MARC details
| 000 -LEADER |
| fixed length control field |
03571ntm a2200289 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000093872 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113316.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
160316t2015 my da f ab m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0000974(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905271117 |
| Level of effort used to assign nonsubject heading access points |
nazirah |
| Level of effort used to assign subject headings |
201710111626 |
| Level of effort used to assign classification |
aishah |
| Level of effort used to assign subject headings |
201603161620 |
| Level of effort used to assign classification |
asma |
| -- |
201603161232 |
| -- |
asma |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKKSA .N675 2015 r Thesis |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Norliza Ishak |
| 245 10 - TITLE STATEMENT |
| Title |
Development of multivariate statistical process monitoring using combination MLR-PCA method / |
| Statement of responsibility, etc. |
Norliza Ishak |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2015 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xviii, 132 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD ROM |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Chemical & Natural Resources Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Master of Engineering (Chemical)) -- Universiti Malaysia Pahang – 2015 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 96-112 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The most popular types of process monitoring systems is Multivariate Statistical Process Monitoring (MSPM) which has the most practical method in handling the complicated large scale processes. This is due to the ability of the system in maximizing the usage of abundant historial process data, in such a way that the original data dimensions are compressed and data variations preserved to certain extent in a set of transformed variables by way of linear combinations. Thus, the composite model is generally flexible regardless of the amount of variables that utilized. In this regard, conventional Principal Component Analysis (PCA) has been widely applied to conduct such compression function particularly for MSPM. However, the conventional PCA is a linear technique which results sometimes inappropriately employed especially in modeling processes that exhibit severe non-linear correlations. Therefore, a new solution is demanded, whereby the number of original variables can be reduced to certain extent (in terms of scales), while it still can maintain the variation as maximally as possible corresponding to the original, which are then transferable into monitoring statistics. One of the potential techniques available in addressing the issue is known as Multiple Linear Regression (MLR). The main objective of the technique is to predict a set of output values (criterion) based from a specified of linear function, which consists of a set of predictor. Therefore, the main multivariate data will be divided into two groups, which are the criterion and predictor categories. The study adopts, Tennessee Eastman Process (TEP) and Multiple Output and Multiple Input (MIMO) Pilot Plant System for demonstration. The general finding is that MLR-PCA normally employs less number of PCs compared to PCA, and thus, this will perhaps reduce complication during diagnosis. By adopting such approach, the monitoring task can be made simpler and perhaps more effective, in the sense that only those selected criterion variables (predicted values) will be taken for monitoring, while preserving the rest of the predictor value trends in the form of linear functions in association with the criterion variables. This study also shows that MLR-PCA works relatively better in terms of fault detection and identification against the conventional system |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Chemical & Natural Resources Engineering |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and Colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| 856 40 - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
<a href="http://ecollib.ump.edu.my/3542/">http://ecollib.ump.edu.my/3542/</a> |
| Public note |
Library access only |