Water quality assessment of Putrajaya Lake for alternative source of water supply / (Record no. 6555)

MARC details
000 -LEADER
fixed length control field 03514ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000094378
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113318.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160408t2015 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000293(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141623
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201712081609
Level of effort used to assign classification saini
-- 201604081121
-- shima
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .A65 2016 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nur Aqilah Mohd Sabandi
245 10 - TITLE STATEMENT
Title Water quality assessment of Putrajaya Lake for alternative source of water supply /
Statement of responsibility, etc. Nur Aqilah Binti Mohd Sabandi
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 91 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors Engineering (Hons.) Civil Engineering) -- Universiti Malaysia Pahang – 2016
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p.68-71
520 3# - SUMMARY, ETC.
Summary, etc. This study focused on determining water quality of Putrajaya Lake. Water Quality is an important guideline to describe the physical, chemical, and biological properties of water that classified them into each class with different suitable purposes. A study was conducted on physical, chemical, and biological parameter of Putrajaya Lake in 2015 water bodies at five stations with three times sampling in the month of September, October, and November. Physical parameters were temperature and suspended solids. Whereas, chemical parameters were pH, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), ammoniacal nitrogen, and selected heavy metals. Biological parameter were Total Coliform and E. Coli. The water was classified based on Water Quality Index (WQI) and National Water Quality Standard for Malaysia (NWQS). According to WQI, the classifications of water quality were based on each station. The most stations in Putrajaya Lake were classified into Class I and II. Station 3 possessed the highest quality surface water sources with WQI value 95 and belongs to Class 1. Station 4 followed by 92, continues with Station 2, Station 5, and Station 1 with value 91,89, and 87 respectively and all of them belong to Class II. Based on NWQS, Most of parameters are belong to Class I. However, BOD, DO, Total Coliform, and lead presence are belongs to Class II. Station 4 chosen as most suitable sources for alternative water supply. The large area covered is the characteristic include in choosing Station 4 as the most suitable alternative water supply. However, in order to provide safe water supply, the raw water sources need to undergo conventional water treatment. According to the Raw Drinking Water Quality Standard the water in Lake Putrajaya did not pass the standards for COD and lead. The main source of lead in the Putrajaya Lake is due to the boating activities that became attraction of Putrajaya. Therefore, it is important to apply new technologies and ideas to control lead contamination. Overall, water quality determination is important to identify different suitable purpose of water body. It is important to conserve and preserve the source of surface water for water supply purpose to avoid water shortage in future.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/4143">http://ecollib.ump.edu.my/id/eprint/4143</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .A65 2016 r Bc. 0000108216 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 9744 | FKASA .A65 2016 r Bc. 0000108217 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us