Fabrication of chromatographic membrane via surface-grafted membrane for protein separation / (Record no. 6620)

MARC details
000 -LEADER
fixed length control field 03613ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000093877
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113321.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160316t2015 my a f 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000922(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905241643
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201710111625
Level of effort used to assign classification aishah
-- 201603161258
-- huda
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKKSA .I99 2015 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nurul Izwanie Rasli
245 1# - TITLE STATEMENT
Title Fabrication of chromatographic membrane via surface-grafted membrane for protein separation /
Statement of responsibility, etc. Nurul Izwanie Rasli
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent xxi, 90 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
500 ## - GENERAL NOTE
General note Faculty of Chemical & Natural Resources Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Engineering (Chemical)) -- Universiti Malaysia Pahang – 2015
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 80-89
520 3# - SUMMARY, ETC.
Summary, etc. Chromatography process was used extensively for protein separation in biotechnology industry. Chromatography resin bead was normally packed in cylindered column during the operation. However there were limitation on using packed bed chromatography such as high pressure drop, low processing rate and slow binding. Membrane chromatography has ability to overcome the limitation of the conventional packed bed chromatography for protein separation. Membrane chromatography used an adsorptive membrane that carried specific chromatography functionality. In the current study, commercial polyamide (PA) microfiltration membrane was modified with acrylic acid monomer to prepare a membrane chromatography. Two modification methods were compared which are ultra violet (UV) photo grafting and chemical grafting via redox reaction. Modification parameters were studied using One Factor at Time (OFAT) which are initiator concentration (1-50 mM), monomer concentration (0.2-5 M) and grafting time (5-60 minutes). The best grafting technique which gave the highest protein binding capacity was achieved by using UV photo grafting. The highest lysozyme (LZY) binding capacity achieved was 0.175 mg LZY/cm2 membrane for the membrane prepared via UV photo grafting using 10 mM of benzophenone (BP) photo-initiator, 0.1 M of acrylic acid (AA) and 15 minutes of reaction time. The best conditions of UV photo grafting modification obtained from OFAT study were used in Response Surface Methodology (RSM) for optimization of protein binding. Based on the analysis of variance (ANOVA), the quadratic model was chosen with the R squared of the model was 0.9468. The optimum value for each parameter studied in RSM was 20.71 mM of BP, 0.29 M of AA and 18.19 min of grafting time. The optimized membrane chromatography was tested and characterized in term of degree of grafting, contact angle measurement, Scanning Electron Microscope (SEM), Fourier Transform InfraRed (FTIR), pure water flux and permeability test. The protein binding capacity at optimized condition was 0.180 mg LZY/cm2. This value is less than 4% of the value predicted by the model. This quadratic model can be used successfully to produce the membrane chromatography from PA membrane through UV grafting for LZY binding.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Chemical & Natural Resources Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/3535/">http://ecollib.ump.edu.my/3535/</a>
Public note Library access only
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKKSA .I99 2015 r Thesis 0000107848 04/09/2019 1 04/09/2019 Thesis
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 9684 | FKKSA .I99 2015 r Thesis 0000107849 04/09/2019 1 04/09/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us