The potential of palm oil fuel ash as partial sand replacement in concrete / (Record no. 6728)

MARC details
000 -LEADER
fixed length control field 03685ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000099255
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113325.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170420t2017 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000433(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151446
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201712061207
Level of effort used to assign classification huda
-- 201704201153
-- fateeha
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .H34 2017 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamad Hafizuddin Rasid
245 14 - TITLE STATEMENT
Title The potential of palm oil fuel ash as partial sand replacement in concrete /
Statement of responsibility, etc. Mohamad Hafizuddin Rasid
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 61 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering (Hons.)) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 54-58
520 3# - SUMMARY, ETC.
Summary, etc. The consumption of natural sand taken from the river was too high due to its excessive use in concrete. The demands for this natural sand were increasing from time to time, especially on developing countries, for instance, Malaysia. Thus, the construction industries are in stress to identify alternative methods and materials to reduce the demand for natural sand. Palm oil fuel ash has been seen as one of the alternative that can replace sand in concrete mixture production and therefore could reduce the excessive production of palm oil fuel ash. In 2011, Malaysia has been reported that 5 million ha area of the land was used for oil palm plantation. This resulted in the annual production of about 61.1 million tone of solid waste such as empty fruit branches, fibres and kernels in the country. It’s also produced about 3 million tons of POFA in 2007. This situation will contribute to increasing of agro waste generated and could led to environmental issues. The main aim of this research is to study the mechanical performance of concrete containing palm oil fuel ash as partial sand replacement. The objectives of this study is to investigate the effect of unground palm oil fuel ash as partial sand replacement on workability, compressive and flexural strength of concrete. Two mix were prepared in this research which are control mix and modified mix. Where the modified mix consist various percentage of palm oil fuel ash as partial sand replacement, which are 0 to 20%. The size of the specimens that is going to be use is 100x100x100 mm (length x width x height). The specimens were subjected to water curing for 7, 28, and 60 days period. The specimens then test for workability, compressive strength test, and flexural strength test. The increase of slump value is attributed by the characteristic of POFA as low water absorption. As the POFA content increases, the slump value is increases. The slump value fall in the range of only 100mm to 120mm at water cement ratio of 0.70. The concrete mix made using POFA as partial replacement of sand showed good workability and fluidity similar to normal concrete mixes The test resulted showed that for 10% ratio of POFA in concrete, the increase in the compressive strength was about 19% compared to normal concrete. Similar results were also observed for the flexure. Conclusively, 10% of POFA is the best recommended amount to be used as partial sand replacement to produced concrete with better strength.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/25806/">http://ecollib.ump.edu.my/25806/</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .H34 2017 r Bc. 0000117483 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 10646 | FKASA .H34 2017 r Bc. 0000117484 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us