Analysis of the influence of viscosity to the liquid film flow between two plates (Record no. 6871)

MARC details
000 -LEADER
fixed length control field 03852nmm a2200313 a 4500
001 - CONTROL NUMBER
control field vtls000098387
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113330.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161213s2016 my fq d 001 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005077(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905101552
Level of effort used to assign nonsubject heading access points hanafiah
Level of effort used to assign subject headings 201712121423
Level of effort used to assign classification fateeha
-- 201612131137
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKP .A936 2016 r Bc.
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) CD 10406
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Azdnan Amat
245 10 - TITLE STATEMENT
Title Analysis of the influence of viscosity to the liquid film flow between two plates
Medium [electronic resource] /
Statement of responsibility, etc. Muhammad Azdnan Amat
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 1 computer disc :
Other physical details digital data ;
Dimensions 12 cm.
500 ## - GENERAL NOTE
General note Faculty of Manufacturing Engineering
500 ## - GENERAL NOTE
General note Theses Gred B
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelor of Engineering in Manufacturing Engineering (Hons.)) -- Universiti Malaysia Pahang – 2016
520 3# - SUMMARY, ETC.
Summary, etc. This thesis deals with analysis of the influence viscosity to the liquid film flow between two plates. How the different viscosity of liquid film can lead to the time taken to full-filling the gap between the two plates? What is the filling pattern of the liquid film upon flowing through the gap? Thus, the objective of this thesis are to analyze the time taken for liquid to full filling the gap between two plates influenced by different liquid viscosity and visualize the flow pattern of the liquid flow upon flowing through the gap between two plates. The procedures to do this project state as following. The two plates of glasses are prepared and the length and width of both plates are measured. The gap between the two plates is set to 50 μm, approximately by using double sided-tap. Then the liquid with 1cSt is sucked by syringe. After that the liquid is injected into the gap. The time taken is recorded to filling up the gap. In addition, the video is taken during the process of liquid film advancement. The experiment is repeated for two more times to get the average time taken and liquid film behavior is observed during the filling up process. The procedure is repeated with 100 cSt, 800 cSt and 10000 cSt of liquid. From the results, it is observed that the analysis with helping of Video to JPEG converter Software and Photoshop Software yields more accurate data then. Ho just using only stopwatch and scaling ruler. The acquired results show the relationship between viscosity and filling time and distance travelled under 10 seconds. The liquid with 1 cSt which is the most lowest produced shortest time taken compared to 100 cSt, 800 cSt and 10000 cSt. While the most higher liquid viscosity that is 10000 cSt would had shortest distance travelled of flow advancement within 10 seconds. On top of that, the preliminary results in determining liquid volume used really important in order to optimize the utility of using liquid viscosity. For the experiments, 3 ml of volume of liquid is the optimum volume for the liquid viscosity to flow between two plates stress. The obtained results indicate that the flow pattern of each liquid viscosity can be different. However, the ideal flow pattern showed in this thesis. The results concluded that the viscosity and flow pattern are affects the flowing liquid between two plates. Therefore, viscosity played a vital role for study the liquid flow for underfill process. The results can also significantly reduce the cost and time to market, and improve product reliability and sustainability.
538 ## - SYSTEM DETAILS NOTE
System details note Item in PDF format
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Manufacturing Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/3944">http://ecollib.ump.edu.my/id/eprint/3944</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKP .A936 2016 r Bc. | CD 10406 0000115921 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us