Seismic performance of cantilever retaining wall structure under earthquake loading / (Record no. 6927)

MARC details
000 -LEADER
fixed length control field 02189ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000099438
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113332.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170425t2017 my da f am 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000552(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151626
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201712071606
Level of effort used to assign classification saini
-- 201704251223
-- nazri
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .L88 2017 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmad Lutfi Mohd Yusof
245 10 - TITLE STATEMENT
Title Seismic performance of cantilever retaining wall structure under earthquake loading /
Statement of responsibility, etc. Ahmad Lutfi Mohd Yusof
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 50 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 50
520 3# - SUMMARY, ETC.
Summary, etc. Retaining wall structures in Malaysia region are placing more emphasis on lateral earth pressure rather than seismic effect. However, Malaysia actually experienced tremors due to the earthquakes occurred in the neighbouring countries. Therefore, the main objective of this research is to study the behaviour of retaining wall structure under earthquake loading and to determine acceleration and displacement of retaining wall structure during earthquake. Hence, a finite element seismic response simulation of a retaining wall structure using SAP2000 has been presented. Time history, response spectrum and free vibration analysis has been carried out and compared throughout this study. Generally, retaining wall structures in Malaysia region are capable of resisting low seismic activity based on the study. This is happen because the design of retaining wall structures for lateral earth pressure can provide sufficient resistance against potential low seismic effects.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/25707">http://ecollib.ump.edu.my/id/eprint/25707</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .L88 2017 r Bc. 0000117469 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 10639 | FKASA .L88 2017 r Bc. 0000117470 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us