Process development of the device using in-house plate-to-plate tool with nanoimprint lithography technique for biochip application / (Record no. 7026)

MARC details
000 -LEADER
fixed length control field 03130nam a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000099871
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113335.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170503t2016 my a f a m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005169(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141019
Level of effort used to assign nonsubject heading access points hanafiah
Level of effort used to assign subject headings 201710041156
Level of effort used to assign classification aishah
Level of effort used to assign subject headings 201705151151
Level of effort used to assign classification saini
-- 201705031249
-- fateeha
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKEE .B44 2016 r Thesis
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Beh, Khi Khim
245 10 - TITLE STATEMENT
Title Process development of the device using in-house plate-to-plate tool with nanoimprint lithography technique for biochip application /
Statement of responsibility, etc. Beh Khi Khim
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 93 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 2 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Electrical and Electronics Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Engineering (Electronic)) -- Universiti Malaysia Pahang – 2016
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 68-75
520 3# - SUMMARY, ETC.
Summary, etc. Biochip is a promising device with capabilities of performing sorting, trapping and screening a large number of biological samples in a short time. Fabrication of biochip pattern process leads to an opening study towards the development of a working biochip. The traditional photolithography process have a limitation in achieving high throughput for biochip pattern fabrication. In this research, the fabrication process of biochip pattern was developed and the imprint parameter for biochip pattern using an in-house assembled plate-to-plate tool was investigated. The biochip patterns are prepared from existing projection lithography to create the mold. Using soft lithography technique, the biochip pattern was replicated invertly in the PDMS mold. The PDMS mold and in-house plate-to-plate fulfilled the requirement for UV-NIL to imprint biochip patterns on a flexible substrate. Dimension error difference (DED) is the difference between the original design dimensions to fabricated design dimensions. DED was characterized and investigated for precise pattern transfer. UV exposure of 140 W was able to produce the satisfied imprint pattern in biochip pattern mold fabrication. However, higher UV energy caused overexposure in the resist, resulting wider width and bridging. Besides that, crack regions were found when post bake exposure parameters are not properly optimized. The DED between biochip pattern mold and PDMS mold are less compared to biochip pattern mold fabrication in the photolithography process. Critical dimension in the biochip pattern was maintained in the imprint process. However, the higher imprint force will cause an overflow of the resist on the substrate, resulting unsatisfied pattern structure. The proposed parameters for imprinting biochip patterns using in-house plate-to-plate tool are 80 N range and 20 seconds of UV exposure.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Electrical and Electronics Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/25879/">http://ecollib.ump.edu.my/25879/</a>
Public note Library access only
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type Public note
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKEE .B44 2016 r Thesis 0000117809 04/09/2019 1 04/09/2019 Thesis  
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 10761 | FKEE .B44 2016 r Thesis 0000117810 04/09/2019 1 04/09/2019 Thesis  
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKEE .B44 2016 r Thesis 0000117822 04/09/2019 2 04/09/2019 Thesis c.2
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 10767 | FKEE .B44 2016 r Thesis 0000117823 04/09/2019 2 04/09/2019 Thesis c.2

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us