Durability of foamed concrete with processed spent bleaching earth as partial replacement of cement under chloride environment / (Record no. 7251)

MARC details
000 -LEADER
fixed length control field 03460ntm a2200277 a 4500
001 - CONTROL NUMBER
control field vtls000102704
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113343.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180108t2017 my a f a m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000767(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161454
Level of effort used to assign nonsubject heading access points nazirah
-- 201801081508
-- fateeha
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .T56 2017 r Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Ting, Qiang Chao
245 10 - TITLE STATEMENT
Title Durability of foamed concrete with processed spent bleaching earth as partial replacement of cement under chloride environment /
Statement of responsibility, etc. Ting Qiang Chao
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 58 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 45-47
520 3# - SUMMARY, ETC.
Summary, etc. Formerly, the uses of the pozzolan materials such as fly ash, silica fume and ground granulated blast-furnace slag as replacement in the production of the concrete have proven to increase the durability of the concrete due to its pozzolanic effect. Besides the utilization of pozzolan materials from the industrial waste as a construction materials lead to reduce the cost of construction materials and reduce the environmental impact from the waste. Processed Spent Bleaching Earth (PSBE) is the SBE that has been treated and can be used as a partial replacement for cement in the foamed concrete due to its pozzolanic effect. The objective of the study is to investigate the effect of the Processed Spent Bleaching Earth in increasing the durability of the foamed concrete against chloride attack. Four mixtures of foamed concrete were design for density of 1600 kg/m3. Foamed concrete (FC) mix with 100% OPC was designed as basic control mix. Processed Spent Bleaching Earth Foamed Concrete mixes (PFC) were designed by partial replacement of cement with 10%, 20% and 30% of PSBE by weight of cement namely as PFC1, PFC2 and PFC 3 respectively. In this study, cube specimen 100mm x 100mm x 100mm and cylinder specimen 200mm diameter x 100mm were prepared and tested based on ASTM C513-11 and ASTM C1202 for compressive strength and durability of foamed concrete towards chloride environment. All specimens were subjected to water curing for 28 days before immersed in the 5% Sodium Chloride solution with pH 6.5 for 7, 28, 60 and 90 days. The behaviour of foamed concrete specimen was observed weekly where the physical and mass loss of the specimens was measured at every week until the end of testing procedure. The cylinder specimens were prepared for rapid chloride permeability test (RCPT) and thermal conductivity test. The findings showed that specimens containing PSBE experienced lower percentage of mass change as compared to control specimen. Results exhibit that 30% of PSBE performed better performance in strength and durability of foamed concrete exposed to chloride environment. In addition, the physical deterioration of 30% of PSBE was lower than control mixture. Hence, the integration of PSBE as partial cement replacement enhances the resistance of foamed concrete towards chloride environment.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .T56 2017 r Bc. 0000121039 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 11078 | FKASA .T56 2017 r Bc. 0000121040 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us