Effect of tube inclination angle on the thermal and fluid dynamic performance of flat tube heat exchanger / (Record no. 7260)

MARC details
000 -LEADER
fixed length control field 04965ntm a2200277 a 4500
001 - CONTROL NUMBER
control field vtls000101555
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113344.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171004s2017 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005283(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151024
Level of effort used to assign nonsubject heading access points hanafiah
-- 201710041449
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKM .Y68 2017 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Yousif Adam Mohammed
245 10 - TITLE STATEMENT
Title Effect of tube inclination angle on the thermal and fluid dynamic performance of flat tube heat exchanger /
Statement of responsibility, etc. Ahmed Yousif Adam Mohammed
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 141 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
500 ## - GENERAL NOTE
General note Faculty of Mechanical Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Engineering in Mechanical) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 120-129
520 3# - SUMMARY, ETC.
Summary, etc. At the present time, the performance of finned and flat tube heat exchangers (HEs) has become a very important issue in the thermal industrial sector. Finned-and-flat tube heat exchangers have gained great interest from many researchers due to their role in any thermal engineering system. Some geometrical and process parameters such as fin spacing, tube spacing, tube inclination angle, etc. affects the performance of fin-and flat tube heat exchangers. Significant number of research have been done to study the effect of such geometrical and process parameters. However, the effect of flat tube inclination angle on the thermal-hydraulic performance of fin-and-tube HE is not fully examined. Thus, the aim of this study was to investigate the effect of flat tube inclination angle, air velocity and tube configuration on the thermal and flow characteristics of compact fin-and-flat tube heat exchangers. A series of experimental and numerical investigations were carried out to evaluate the influence of the aforementioned parameters on the thermal-hydraulic performance between the tube bundles. Moreover, Response Surface Methodology (RSM) was used to determine the optimum parameter condition for the fin-and–tube HE. The range of the parameters considered in the study were tube inclination angle from 0˚ to 150˚, inlet air flow velocity from 1.8 to 3.8 m/s and tube configuration (inline and staggered). For the experiments, the wind tunnel available at the Faculty of Mechanical Engineering, UMP was used. The wind tunnel was equipped with a blower of capacity 50 W, flow straightener, test section and measuring sensors. Twelve plate fin and nine flat tube heat exchangers test sections were designed and manufactured at various inclination angles and configurations. Temperature, velocity, and pressure measurements were recorded at various positions in the test section as well as before and after the test section. For the numerical analysis, the CFD commercial software called ANSYS FLUENT-15 was used to solve the Navier-Stoke and energy equations together with proper turbulent equations. The parameters are similar to the experimental investigation. The experiment and numerical analysis used Nusselt number, pressure drop, and area goodness factor to evaluate the thermal-hydraulic performance of fin-and-flat tube heat exchangers. The major findings showed that flat tube inclination angle has significant impact on the heat transfer enhancement. However, the results from both experimental and numerical analysis revealed that increasing the tube inclination angle from 0˚ to 90˚ augments the convective heat transfer coefficient. While 120˚ and 150˚ provide thermal performance close to 60˚ and 30˚, respectively. The average deviations of Nusselt number between experimental and numerical results were 5.42% and 4.44% for inline and staggered configurations respectively. Moreover, due to the air flow blockage caused by inclining the tube angle, the pressure drop increases dramatically for all cases studied. From all acquired results, the best thermal performance occurred at 0˚, while 90˚ provided the minimum thermal performance. Therefore, inclining the tube is beneficial for enhancing the heat transfer performance but is not beneficial in term of pressure drop as it requires higher pumping power. The developed correlations from the RSM can predict experimental data with average deviation of 2.78% for Nu for both configurations. Moreover, it can predict the numerical data with average deviation of 0.554% and 0.92% for inline and staggered configuration, respectively. The optimum parameters are found to be with high air velocity and low tube inclination angle which provide maximum heat transfer enhancement and low-pressure drop penalty. Thus, it is recommended for the design of fin-and-flat tube HEs.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Mechanical Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKM .Y68 2017 r Thesis 0000119754 04/09/2019 1 04/09/2019 Thesis
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 10841 | FKM .Y68 2017 r Thesis 0000119755 04/09/2019 1 04/09/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us