MARC details
| 000 -LEADER |
| fixed length control field |
02130ntm a2200277 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000102726 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113345.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
180111t2017 my da f am 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0000572(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905160925 |
| Level of effort used to assign nonsubject heading access points |
nazirah |
| Level of effort used to assign subject headings |
201801111119 |
| Level of effort used to assign classification |
nazri |
| -- |
201801111116 |
| -- |
nazri |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKASA .M85 2017 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Abdul Mu’iz Embong |
| 245 10 - TITLE STATEMENT |
| Title |
Study of water quality for rain water harvesting systems on roof material / |
| Statement of responsibility, etc. |
Abdul Mu’iz Bin Embong |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2017 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xii, 46 p. : |
| Other physical details |
ill. (some col.), charts ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Civil Engineering and Earth Resources |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 37-38 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Rainwater harvesting have a potential to be next sources of clean water besides tap water. Two objectives of this study are to study water quality of potential roof material for rainwater harvesting systems in UMP buildings and to suggest an appropriate water treatment in order to improve quality of harvested rainwater. In this study, three different roof types were investigated, which is Clay roof, Metal deck roof and Concrete flat roof and ambient rainwater as a control sample. Rainwater sample was collected in 3 different rain events. Water quality in this study is determined by doing tests on 9 parameters which is; pH, temperature, conductivity, total suspended solid (TSS), turbidity, nitrate, nitrite, total coliform and Escherichia Coli (E-Coli). The proposed treatment for harvested rainwater is chlorination, UV filtration, Sand Gravel filters and reverse osmosis. All these guidelines gained from the WHO Drinking Water Standards 1993 and National Water Quality Standards of Malaysia. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Civil Engineering and Earth Resources |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and Colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |