Effect of column size on the seismic capacity of elevated reinforced concrete water tank / (Record no. 7366)

MARC details
000 -LEADER
fixed length control field 03037ntm a2200277 a 4500
001 - CONTROL NUMBER
control field vtls000102664
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113348.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180104s2017 my da f am 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000233(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141456
Level of effort used to assign nonsubject heading access points nazirah
-- 201801041302
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .A357 2017 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Afiqah Azeera Awang Damit
245 10 - TITLE STATEMENT
Title Effect of column size on the seismic capacity of elevated reinforced concrete water tank /
Statement of responsibility, etc. Afiqah Azeera Awang Damit
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent xi, 64 p. :
Other physical details ill. (some col.), charts ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 49-51
520 3# - SUMMARY, ETC.
Summary, etc. One of the major natural calamities is earthquake which have the potential to cause damage to lives and lifeline facilities. Malaysia have experienced many earthquakes from surrounding regions and several local earthquakes. Therefore, it has become a necessary to evaluate the safety of buildings in Malaysia when subjected to seismic action. Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of the methods used to evaluate the seismic capacity of elevated reinforced concrete water tank is the pushover analysis. Pushover analysis is based on the assumption that structure oscillate predominantly in the first mode or in the lower modes of vibration during a seismic event. The objective of this project is to study the effect of column size on the seismic capacity of elevated reinforced concrete water tank. A total number of 10 models of elevated reinforced concrete water tanks consist of 4 storeys and 7 storeys has been used for this project. All models have been designed repeatedly to 5 different size of column, where the beam size is fixed for each model. All models have been designed based on BS8110 to represent the existing elevated reinforced concrete water tanks. Then the pushover analysis has been conducted on all models to study the seismic capacity of elevated reinforced concrete water tank. An adequate information on seismic demands imposed on the structural system and its components by the designed ground motion are provided from the pushover analysis. Based on the pushover analysis conducted in this study, the elevated RC water tank with larger size of column tend to have higher value of force at yield state and ultimate state.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .A357 2017 r Bc. 0000120878 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 10985 | FKASA .A357 2017 r Bc. 0000120879 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us