Flow and heat transfer characteristics of supercritical carbon dioxide in mini-channels / (Record no. 7647)

MARC details
000 -LEADER
fixed length control field 04313ntm a2200373 i 4500
001 - CONTROL NUMBER
control field vtls000103165
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113358.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180326t20182018my da f am 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005277(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141732
Level of effort used to assign nonsubject heading access points hanafiah
Level of effort used to assign subject headings 201903211648
Level of effort used to assign classification saini
-- 201803261227
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKM .T45 2018 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Thiwaan Rao Narasimma Naidu,
Relator term author.
245 10 - TITLE STATEMENT
Title Flow and heat transfer characteristics of supercritical carbon dioxide in mini-channels /
Statement of responsibility, etc. Thiwaan Rao A/L Narasimma Naidu
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2018
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2018
300 ## - PHYSICAL DESCRIPTION
Extent xvii, 117 pages :
Other physical details illustrations (some color), charts ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Mechanical Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Science in Mechanical Engineering) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Supercritical carbon dioxide (scCO2) is being used in many engineering applications because at supercritical stage, it has unique thermal properties with enhanced heat transfer and flow characteristics. Carbon dioxide (CO2) at supercritical phase is being used recently in Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) industries due to its special thermal properties of supercritical CO2. However, the effects of some process and geometrical parameters on the thermal hydraulic performance of scCO2 are not fully examined. Thus, the aim of this study is to develop single phase flow and heat transfer model and to investigate the effect of some process parameters (inlet pressure, inlet temperature, and inlet flow rate) and geometrical parameters (Tube inner diameter and tube shape) on the performance of scCO2 cooling process. For the numerical investigation, two cases were considered: straight and helical tubes at various tube diameters. The model was developed based on the assumption that the scCO2 flow is incompressible, turbulent and non-isothermal. The developed numerical model was validated using experimental data from open literature for the straight tube and by conducting experiments for the helical tube case. Both the simulation and experiment were performed at various input parameter range: pressure (7.0 MPa – 10 MPa), temperature (35 ºC – 80 ºC), flow rate (10 L/min – 35 L/min) and tube diameter (2.8 mm – 4.5 mm). The model validation results indicated that the average percentage error between the simulation and experimental results were less than 10%. This indicates that the developed model can be used to predict the performance of scCO2 cooling process. Both the experimental and simulation results indicated that the heat transfer coefficient reaches peak value near the pseudo-critical point. Heat transfer coefficient decreased as inlet pressure increased beyond critical point but increased with increasing flow rate. Meanwhile, highest pressure drop value was recorded near the critical point. On the other hand, the smaller the inner tube diameter the higher the heat transfer coefficient will be. The pressure drop in a system decreased when the system inlet pressure is increased but increased with increasing flow rate. Besides, the sensitivity analysis results of Nusselt number and pressure drop indicate that the best input parameters in scCO2 cooling. Inlet pressure with value near critical point, smaller tube ID and higher flow rate could achieve both enhanced heat transfer and low pressure drop at the same time. However, increasing inlet temperature could deteriorate heat transfer rate even though lower pressure drop was attained. These parameter combinations could help reducing the pumping power associated with pressure drop.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Mechanical Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Disertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 11255 | FKM .T45 2018 r Thesis 0000122637 04/09/2019 1 04/09/2019 Thesis
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKM .T45 2018 r Thesis 0000122636 04/09/2019 1 04/09/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us