MARC details
| 000 -LEADER |
| fixed length control field |
02761ntm a2200373 i 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000102908 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113358.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
180130s2017 my da f a m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0000940(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905271032 |
| Level of effort used to assign nonsubject heading access points |
nazirah |
| Level of effort used to assign subject headings |
201802081611 |
| Level of effort used to assign classification |
fateeha |
| Level of effort used to assign subject headings |
201802050852 |
| Level of effort used to assign classification |
fateeha |
| -- |
201801301258 |
| -- |
fateeha |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKKSA .L56 2017 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Lina Nabilah Luqman Loke, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Effect of the size of multi-layer spacer configuration on membrane performance : |
| Remainder of title |
a CFD study / |
| Statement of responsibility, etc. |
Lina Nabilah Luqman Loke |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2017 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2017 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
x, [unpages] : |
| Other physical details |
illustrations (some color), charts ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 337 ## - MEDIA TYPE |
| Media type term |
computer |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 338 ## - CARRIER TYPE |
| Carrier type term |
computer dics |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Chemical & Natural Resources Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project Paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2017 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The spiral wound membrane (SWM) module are the membrane technology for water treatment and the Reverse Osmosis (RO) membrane process is currently leading method and implemented through SWM. SWM module formed by two neighbouring membrane sheets separated by a thin net-type spacer where the separation take place. It come in multiple configurations with different spacer geometry, membrane types and size. Moreover, concentration polarization is strongly affect the performances of separation process. Spacer will reduce the extent of concentration polarization because of the enhanced wall shear thus increase the flux of the membrane. Besides, fouling also result of the concentration polarization. Fouling will increase as the concentration polarization increase then result in loss of permeate flux. Therefore, the objective of this study is to investigate the effect of the size of multilayer spacer configuration on permeate flux and concentration polarization. In the investigation, we want to reduce the concentration polarization by using difference geometry multilayer spacer configuration. Besides, ANSYS Fluent v16.2 is used to develop the 3D multilayer spacer, CFD modelling and flow of simulation. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Chemical & Natural Resources Engineering |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and Colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |