MARC details
| 000 -LEADER |
| fixed length control field |
02907ntm a2200361 i 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000104334 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113404.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
180719s2018 my a f a m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0001310(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905141010 |
| Level of effort used to assign nonsubject heading access points |
asmadi |
| Level of effort used to assign subject headings |
201808131528 |
| Level of effort used to assign classification |
fateeha |
| -- |
201807191103 |
| -- |
fateeha |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FTeK .A33 2018 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Aida Khairani Ariffin, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Exposure assessment of indoor fine particulate matter 2.5 (PM2.5) in bound to heavy metals among shop in urban area of Kuantan / |
| Statement of responsibility, etc. |
Aida Khairani Ariffin |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2018 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xvi, 81 pages : |
| Other physical details |
illustrations (some color) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 337 ## - MEDIA TYPE |
| Media type term |
computer |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 338 ## - CARRIER TYPE |
| Carrier type term |
computer disc |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Engineering Technology |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project Paper (Bachelor of Occupational Safety and Health (Hons.)) -- Universiti Malaysia Pahang – 2018 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Heavy metals may come from many different sources to the urbanized area. One of the most important heavy metals source is vehicle emission. The concentrations of several types of heavy metals were measured in indoor dust from five different shop vendors at two different roads which is Jalan Mahkota and Jalan Besar in urban area at Kuantan to illustrate their concentration and their characterization which is chemically and physically. The levels of five types heavy metals in indoor environment shows that Lead (Pb) was the highest concentration compared to four heavy metals which is Cadmium (Cd), Chromium (Cr), Copper (Cu) and Zinc (Zn). Moreover, the study of heavy metals in indoor is important due to their critical effects on human specifically in indoor because 90% most of times people spend in indoor. Furthermore, potential determinants factors of indoor air quality in shops vendors along an urban street also was determined which is air velocity, temperature and relative humidity using instrument which is Anaemometer. The samples collection, preparation and analysis were carried out using standard procedures. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to determine the concentration of heavy metals at the surface of Teflon filter paper. The average of concentration value of Cd, Cr, Cu, Pb and Zn are 0.35 ppb, 19.03 ppb, 6.79 ppb, 36.53 ppb and 0.37 ppb respectively. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Engineering Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Disertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |