MARC details
| 000 -LEADER |
| fixed length control field |
03390ntm a2200373 i 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000105329 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113405.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
180927t20182018my da f am 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005254(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905141527 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| -- |
201809271549 |
| -- |
saini |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKM .M354 2018 r Thesis |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Makeen Mohd Amin, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Leak detection in medium density polyethylene pipe using ensemble empirical mode decomposition method / |
| Statement of responsibility, etc. |
Makeen Mohd Amin |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2018 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2018 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xii, 81 pages : |
| Other physical details |
illustrations (some color), charts ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 337 ## - MEDIA TYPE |
| Media type term |
computer |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 338 ## - CARRIER TYPE |
| Carrier type term |
computer disc |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Mechanical Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Master of Engineering (Mechanical)) -- Universiti Malaysia Pahang – 2018 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Nowadays, there are many approaches to the methods for detecting pipeline’s feature either from external or internal. The only argument is which method will deliver the most effective result with the advantage of time-saving and human-friendly. The results were influenced by the surrounding noise either from inner or the outer pipeline networks. This thesis mainly focuses on the detection features in pipeline network using Ensemble Empirical Mode Decomposition Method (EEMD). The objectives of this thesis are to study and analyse data by using EEMD method for leakage detection in the pipeline system and identify and compare the leakage position between the measured distance and analysed distance. Therefore, the test rig was built by using 56m polyethene pipe with the leak as the main feature. Solenoid valve is used to create water hammering phenomenon. The water hammering phenomenon will generate a transient wave inside the pipe. The data was collected using DASYLab software and analysed using MATLAB software. The leakage and outlet position were determined by undergoing intrinsic mode function analysis (IMF) and later analysed by their respective instantaneous frequency analysis (IF) using EEMD method. The experiment was runs in two situations, firstly by closing the leakage valve and the other one by opening the valve to create leakage. The analysed results show that the position of the outlet is almost similar to the measured distance with 0.55% and 6% of percentage error. The analysed leakage location is also determined and compared to the measured distance. It indicates that only 3.21% of error between the measured distance and analysed distance and analysed distance. It can be concluded that the EEMD analysis is one of the best methods to be the approach in leak detection of either underground or above ground piping system. In addition, this method can be said as low in cost and energy saving. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Mechanical Engineering |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Disertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |