Seismic design for reinforced concrete hospital building influenced by level of peak ground acceleration and class of ductility / (Record no. 7873)

MARC details
000 -LEADER
fixed length control field 03838ntm a2200361 i 4500
001 - CONTROL NUMBER
control field vtls000105640
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113406.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190423t20182018my ab f am 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000389(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141805
Level of effort used to assign nonsubject heading access points nazirah
-- 201904231220
-- nazri
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .F373 2018 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Farashaheeda Ahmad Jani,
Relator term author.
245 10 - TITLE STATEMENT
Title Seismic design for reinforced concrete hospital building influenced by level of peak ground acceleration and class of ductility /
Statement of responsibility, etc. Farashaheeda Ahmad Jani
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2018
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2018
300 ## - PHYSICAL DESCRIPTION
Extent ix, 56 pages :
Other physical details illustrations (some color), maps (some color) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. A series of earthquakes such as Sumatra-Andaman earthquake on 26 December 2004, Nias earthquake on 28 March 2005, and Bengkulu earthquake on 12 December 2007 had influences to a series of subsequence local earthquake in Peninsular Malaysia. Some of the local earthquake that had been affected are at Bukit Tinggi on 30 November 2007 to 25 May 2008, Jerantut on 17 March 2009, Manjong on 29 April 2009, and Kuala Pilah on 29 and 30 November 2009. While in East of Malaysia especially Sabah, it is locally known as earthquake prone region. Hence it can be concluded that Malaysia is not totally free from seismic activities either in peninsular Malaysia or at the east of Malaysia. In 2009, Malaysia Public Work of Department (PWD) felt it was worthwhile to consider seismic design input in new building which are located in medium to high risk earthquake zone. The effect of seismic design implementation on cost of materials is became an important topic to be investigated. In relation to that, this study discusses on the seismic design of reinforce concrete hospital building with consideration of different magnitude of Peak Ground Acceleration (PGA) and different class of ductility. The outcome of the design is the comparison on the amount of steel reinforcement required that is obtained from two different parameters mentioned above compared to non-seismic design. Six models of hospital buildings with consideration of different PGA and ductility class are considered, namely, non-seismic building, medium ductility with PGA of 0.04g, 0.08g, 0.12g, 0.16g and low ductility with PGA of 0.04g. For different magnitude of PGA, the results shows that the percentage difference of steel reinforcement required compared to non-seismic design for beam and column of the whole building had increased from 6%, 116%, 257%, and 290% for PGA equals to 0.04g, 0.08g, 0.12g, and 0.16g respectively. While for different class of ductility, the results shows that the percentage difference of steel reinforcement required compared to non-seismic design had increased from 6% to 145% for ductility class medium and ductility class low respectively. Thus, magnitude of PGA and class of ductility of structure give significant effect to overall amount of steel reinforcement required. Hence, it should be considered in designing a seismic building.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Disertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .F373 2018 r Bc. 0000126981 04/09/2019 1 04/09/2019 Final Year Report
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 11910 | FKASA .F373 2018 r Bc. 0000126982 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us