MARC details
| 000 -LEADER |
| fixed length control field |
03982ntm a2200349 i 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000104492 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113407.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
180725s2018 my da f am 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005181(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905141434 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201905141433 |
| Level of effort used to assign classification |
hanafiah |
| -- |
201807251126 |
| -- |
saini |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKEE .H36 2018 r Thesis |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Hammid, Ali Thaeer, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Optimization and control of hydro generation scheduling using hybrid firefly algorithm and particle swarm optimization techniques / |
| Statement of responsibility, etc. |
Ali Thaeer Hammid |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2018 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xvii, 172 pages : |
| Other physical details |
illustrations (some color), charts ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 337 ## - MEDIA TYPE |
| Media type term |
computer |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 338 ## - CARRIER TYPE |
| Carrier type term |
computer disc |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Electrical and Electronics Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Doctor of Philosophy of Engineering in Electrical and Electronics) -- Universiti Malaysia Pahang – 2018 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The fundamental requirement of hydropower system scheduling is to determine the optimal amount of generated powers for the hydro unit of the system in the scheduling horizon of 1 year or few years while satisfying the constraints of the hydroelectric system. Annual hydro generation scheduling (AHGS) is a complicated non-linear, non-convex and non-smooth optimization problem with discontinuous solution space. The model considers daily water inflows, limits on reservoir level, power generation depends on the available head of hydro units caused by power variations, start-up, and shut-down of hydro units. Moreover, hydro generation prediction typically has composite structures such as non-linearity, non-stationarity, and fluctuation due to unexpected variable of input parameters, which converts its prediction to be very tough. Artificial intelligence (AI) methods are normally selected to deal with this problem. However, they are suffering from partial optimization, falling in solutions of local minima, and low speed of convergence. To deal with these problems, this thesis introduces three approved intelligent controllers for hydropower generation. Firstly, a hybrid algorithm namely firefly particle swarm optimization (FPSO) and series division method (SDM) based on the practical swarm optimization and the firefly algorithm is proposed. In the FPSO method, the local search is performed through the modified light intensity attraction step with PSO operator. Secondly, this approach hybridizing the FA with the rough algorithm (RA), where RA is used to control the steps of randomness for the FA while optimizing the weights of the standard BPNN model. After that, the stationary simulation prediction model is obtained. Thirdly, a novel normalized firefly fuzzy control method (NFANN) is designed for stability control of a hydro-turbine system. Moreover, the more relaxed and simplified sufficient stability conditions are given as a new set of right-angle triangle membership function (RFANN), which has been guaranteed by strict mathematical derivation. The proposed methods tested on raw data of hydropower plant of Himreen Lake Dam. The optimal hydropower generation that observed is increased to the maximum over the actual value by PSO, SD-PSO, SD-FA, and FPSO increased by 1.5%, 2.3%, 3.1%, 2.5% respectively. The proposed SD-FA controller showed better and robustness compared to the other algorithm, which could resist the random disturbances. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Electrical and Electronics Engineering |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Disertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |