Heat exposure and its health effects among construction site workers / (Record no. 7975)

MARC details
000 -LEADER
fixed length control field 03199ntm a2200349 i 4500
001 - CONTROL NUMBER
control field vtls000103763
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113410.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180604s2017 my a f a m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0001362(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905211115
Level of effort used to assign nonsubject heading access points asmadi
-- 201806041412
-- fateeha
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FTeK .I99 2017 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Siti Nor Izzati Mat Yaacob,
Relator term author.
245 10 - TITLE STATEMENT
Title Heat exposure and its health effects among construction site workers /
Statement of responsibility, etc. Siti Nor Izzati Mat Yaacob
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2017
300 ## - PHYSICAL DESCRIPTION
Extent xii, 92 pages :
Other physical details illustrations (some color) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Engineering Technology
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelor of Occupation Safety and Health with Honors) -- Universiti Malaysia Pahang – 2017
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Heat stress is the net load to a worker which could be exposed from the contribution of environmental factors, occupational and personal factor. It can induce the heat stress symptoms such as headache and muscle cramps. This cross-sectional was conducted in the construction site to determine environmental monitoring and personal heat stress assessment. Besides, to identify factors that influence personal heat stress. The instruments used in data collection were QUEST Temp034 Thermal Environment Monitor to measure Wet Bulb Globe Temperature (WBGT) index whereas OMRON Digital HEM7200 Blood Pressure Monitor and Infrared Digital Thermometer were used in this study to assess personal monitoring. Meanwhile, questionnaire was used to retrieve information related to heat stress symptoms. There were a total of 40 respondents participated in this study. This study focus on construction site in Kuantan, Pahang. There was a significant differences between ambient temperature and heat index. It also showed that WBGT was significantly higher than heat index. Apart from that, there was no significant correlation between environmental heat exposure (WBGT) and physiological effect (blood pressure and heart rate). Besides that, factor of hydration status and Body Mass Index (BMI) was significantly influence heat stress level among all the factors as the significant value was (p<.05). The prevalence of heat stress symptoms showed that there was several most common symptoms that frequently suffered by workers at construction site such as headache, weakness, fatigue, dizziness, high body temperature and muscle cramps. In conclusion, high environmental temperature had escalated the risk stress exposure and increase the tendency of getting heat-related illness with introduce the heat stress symptoms.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Engineering Technology
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Disertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 11313 | FTeK .I99 2017 r Bc. 0000122861 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FTeK .I99 2017 r Bc. 0000122860 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us