Blast impact on reinforced concrete wall / (Record no. 7988)

MARC details
000 -LEADER
fixed length control field 04697ntm a2200349 i 4500
001 - CONTROL NUMBER
control field vtls000104314
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113410.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180716s2018 my da f am 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000564(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905160913
Level of effort used to assign nonsubject heading access points nazirah
-- 201807161544
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .M39 2018 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mazlan Abu Seman,
Relator term author.
245 10 - TITLE STATEMENT
Title Blast impact on reinforced concrete wall /
Statement of responsibility, etc. Mazlan Abu Seman
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2018
300 ## - PHYSICAL DESCRIPTION
Extent xxi, 211 pages :
Other physical details illustrations (some color), charts ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering & Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Doctor of Philosophy in Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Reinforced concrete (RC) wall is used as a protective structure to reduce the effect of blast overpressure loading to protect the building, personnel or sensitive equipment from the impact of load via explosion. Even though a number of investigations have been carried out to study the blast impact on RC structures, however it is still lack of experimental and numerical research has been academically published regarding its effect on the RC wall. Most of the published work limited on the RC panel. The published experiment and accessible for reference is the work focuses on different steel reinforcement materials used in RC wall. Thus, further investigation is needed for the RC wall subjected to blast load especially on the appropriate steel reinforcement design and effective arrangement. Present work aims to study the behaviour of RC wall subjected to blast load of 13.61 kg Trinitrotoluene (TNT) at 1.219 m standoff distance from the wall centre experimentally and numerically. The AUTODYN non-linear finite element (FE) analysis commercial software is used to develop a validated numerical model against published experimental result such as recorded blast overpressure data and crack patterns occurred on the RC wall surface. Further numerical parametric investigation for blast impact on RC wall is conducted on the effect of different concrete strengths, steel reinforcement ratios, the hooked direction of vertical flexural reinforcement into the RC wall base and the placing of horizontal steel reinforcement on the vertical steel reinforcement in the RC walls. The present experimental study consisted of three RC walls with similar moment resistance capacity but different steel reinforcement arrangements. The experimental setup similar for RC wall at conflict zone area was considered in the blast field and followed by a validated numerical model. Further numerical assessments were conducted for effective steel reinforcement arrangement in RC wall. The present experimental work established that, the appropriate placement for horizontal steel reinforcement is tied outside on the vertical steel reinforcement or next to the concrete cover. In addition, the hooked-in direction of the vertical steel reinforcement into the wall base indicated that the RC wall behavior is improved in terms of the movement and cracks occurred due to the blast load. The numerical investigation indicated that the RC wall with the horizontal steel reinforcement tied outside on the vertical steel reinforcement is capable to distribute strain and kinetic energy evenly between front and back side of the RC wall. Additionally, with the direction of hooked-out of vertical steel changed to hooked-in into wall base, it is possible to increase spacing on horizontal by 13.16% and vertical steel reinforcement by 33.55% where the RC wall demonstrates a comparable strength and resistance to the initial RC wall’s steel reinforcement spacing of 152 mm horizontal 152 mm vertical. Therefore, with the appropriate placement of horizontal steel reinforcement in the RC wall, the resistance to the blast load is increased. Furthermore, with the hooked-in of steel reinforcement into the wall base, the effective amount needed for the RC wall subjected to blast load is observed without compromising as the protective structure.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering & Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Disertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type Collection Shelving location
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .M39 2018 r Thesis 0000123545 04/09/2019 1 04/09/2019 Thesis    
  Not lost Library of Congress Classification   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 11363 | FKASA .M39 2018 r Thesis 0000123546 04/09/2019 1 04/09/2019 Thesis    
  Not lost Library of Congress Classification   Final Processing UMPLIB GAMBANG UMPLIB GAMBANG 02/03/2022   FKASA .M39 2018 r Thesis c.2 T000001074 12/05/2022 2 02/03/2022 Thesis Reference Reference

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us