Power line enhancement for distance data monitoring of human physiological parameters / (Record no. 8713)

MARC details
000 -LEADER
fixed length control field 03627ntm a2200277 a 4500
001 - CONTROL NUMBER
control field vtls000094061
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113436.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160322t2015 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0007787(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201906131112
Level of effort used to assign nonsubject heading access points nadia
-- 201603221127
-- shima
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKEE .S65 2015 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Sridhathan C
245 10 - TITLE STATEMENT
Title Power line enhancement for distance data monitoring of human physiological parameters /
Statement of responsibility, etc. Sridhathan C
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent xx, 135 p. :
Other physical details ill. ;
Dimensions 30 cm.+
Accompanying material 1 CD-ROM
500 ## - GENERAL NOTE
General note Faculty of Electrical and Electronics Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Doctor of Philosophy in Electronic Engineering) -- Universiti Malaysia Pahang -- 2015
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 120-133
520 3# - SUMMARY, ETC.
Summary, etc. In recent years, utilizing the pre-established power distribution line for communications have become more attractive. The patients who are suffering with the chronic diseases must be monitored continuously to reduce the risk in patient’s life. Industries manufacturing healthcare equipment are incorporating the communication system modules for telemedicine, biotelemetry, tele-surgery and tele-health applications. In this research, Power Line (PL) is proposed as a communication medium for transferring the patient’s physiological parameter. Electrodes or transducers are placed on patient at appropriate locations for acquiring the Heart Rate (HR), Blood Pressure (BP), Temperature, Electrocardiogram (ECG) and Electroencephalogram (EEG). Acquired signals are digitalized and transmitted over the single phase PL cable using Power Line Modem (PLM). In this research, Low Voltage Single Phase (LVSP) power distribution cables were used for transmitting and receiving the medical signals. In a medical practitioner's room, receiver decodes the signals and a Personal Computer (PC) is used for display. The characteristic of power line is simulated as echo channel model using MATLAB software in which the data are transmitted using orthogonal frequency division multiplexing (OFDM) method. Performance of the simulated power line channel (SPLC) is evaluated based on the Bit Error Rate (BER). ECG and EEG signals where interfered by noise and disturbance of power line during transmission. Hence, Finite Impulse Response (FIR) filter with Kaiser Window is designed using MATLAB for noise reduction. R peaks of ECG are detected based on Threshold point and proposed adaptive firefly algorithm. ECG of a patient suffering by Sinoatrial block, arrhythmia and sudden cardiac arrest are taken from physio-bank website and were analyzed using Daubechies multilevel wavelet transform. It was observed from the experimental results that parameters such as heart rate, temperature and BP are received without any errors. ECG and EEG signals were distorted due to the PL noise and disturbances. From the simulation results it was found that, the BER can be reduced by increasing the Inverse Fast Fourier Transform (IFFT) size or by increasing the guard bit interval time. Adaptive firefly technique was found to be effective and efficient when compared with threshold point method. It can be concluded that low voltage power line communication using the existing power cables was found to be cost effective with sufficient speed and accuracy
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Electrical and Electronics Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   FKEE .S65 2015 r Thesis 0000107768 04/09/2019 1 04/09/2019 Restricted Collection
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 9644 | FKEE .S65 2015 r Thesis 0000107769 04/09/2019 1 04/09/2019 Restricted Collection

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us