The potential of tube well water quality in Tekek Village, Tioman Island for clean water supply / (Record no. 8727)

MARC details
000 -LEADER
fixed length control field 03699ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000098208
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113436.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161130s2016 my ab f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0007845(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201906131057
Level of effort used to assign nonsubject heading access points nazri
Level of effort used to assign subject headings 201712121052
Level of effort used to assign classification fateeha
-- 201611301015
-- saini
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .G37 2016 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohd Gassry Nazmy Saharudin
245 14 - TITLE STATEMENT
Title The potential of tube well water quality in Tekek Village, Tioman Island for clean water supply /
Statement of responsibility, etc. Mohd Gassry Nazmy Saharudin
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 96 p. :
Other physical details ill. (some col.), maps (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2016
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 59-63
520 3# - SUMMARY, ETC.
Summary, etc. Water is the most essential nutrient to life. Availability of water for cleansing is directly to control or elimination of disease. The quality of water depends on their chemical and physical characteristization which can define as the water was safe and clean. In other to obtain excellent quality of water for consumption, a good water treatment system that will not affected by contaminant that can reduce the water quality. In Tekek Village, the people get the water supply by Gravity Feed System (GFS) but the water supply does not enough to support the water demand from population. Therefore, this study was carried out to determine the tube well water quality based on the physical, chemical and biological parameters. The sampling was conducted during dry and rainy season between 2015 and 2016. Water samples were collected from 3 stations that located in Tekek Village and analysed using standard methods. The parameters tested referred to the Standard Methods for the Examination of Water and Wastewater which was jointly published by American Public Health Association (APHA), the American Water Works Association (AWWA), and the Water Environment Federation (WEF) in 2012. The results showed that pH, Total Suspended Solid (TSS), Turbidity, and Ammonia Nitrogen (NH3N) were within the standard acceptable level of Malaysia Drinking Water Quality Standard (MDWQS) for drinking water purpose. However for the biological parameters which are Total Coliform and E-coli bacteria showed that result were exceeding the maximum acceptable values based on MDWQS. While for the heavy metal parameter, the results show that only Iron (Fe), Manganese (Mn), Zinc (Zn) and Copper (Cu) were within the standard acceptable level of MDWQS for drinking water purpose but the result shown that Lead (Pb) does not following the maximum acceptable value for drinking water. The method of analysis of groundwater that was used is Atomic Absorption Spectroscopy (AAS) to analysis the concentration of heavy metal in water sample. Therefore, the minimum water treatment was needed to make sure Pb could be removed from water. In generally the water sample from station 1 and 2 were categorized as Class I meanwhile for the station 3 it was under Class II based on Water Quality Index (WQI). Therefore, the water from station 1, 2 and 3 can be categorized as clean water but it needed a natural water treatment to remove bacteria that presence in water.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/25719">http://ecollib.ump.edu.my/id/eprint/25719</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .G37 2016 r Bc. 0000114877 04/09/2019 1 04/09/2019 Final Year Report
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 10163 | FKASA .G37 2016 r Bc. 0000114878 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us