Investigation of effective on-site detention pond design using various methods / (Record no. 90811)

MARC details
000 -LEADER
fixed length control field 03766ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125105358.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191008t20192019my ab||f |||| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0008097(Local)
Qualifying information hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .S55 2019 r Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Shirline, Leong Ai Lin,
Relator term author.
245 10 - TITLE STATEMENT
Title Investigation of effective on-site detention pond design using various methods /
Statement of responsibility, etc. Shirline Leong Ai Lin
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2019
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2019
300 ## - PHYSICAL DESCRIPTION
Extent xv, 91 pages :
Other physical details illustrations, maps ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Flash flood and monsoon flood are very common disasters that caused by improper stormwater management. Hence, on-site detention facility plays an indispensable role in stormwater management efforts to reduce probability of flood occurrences. Prior designing on-site detention facility, collection of sufficient time series precipitation data and rainfall data analysis play indispensable role in ensuring the accuracy of on-site detention facility design. In this study, time series rainfall data for the past 30 years were collected and rainfall data gaps were approximated using the Arithmetic Mean method and the consistency of the gap filled rainfall data was evaluated using the Mass Curve method. From the consistency analysis, it was found that Pekan development site has the highest rainfall data consistency followed by Kuantan development site and Jerantut development site. Moreover, the characteristics of on-site detention system is depending on the IDF curve performance which gives the magnitude of rainfall intensity corresponding to various storm duration and ARI. The IDF curves provided in MSMA 2 was not up to the current year. Thus, in this study, IDF curves were developed using Gumbel Type I distribution for the nearest rainfall station to each development site. It was noticed that difference between the study’s IDF curve and MSMA 2 IDF curve appeared to be small for the first 60 minutes of storm duration and gradually increased when the storm duration greater than 60 minutes. This was due to rainfall data considered in developing new IDF curve was only up to 60 minutes. Furthermore, the adoption of on-site detention facility design method determines the cost effectiveness and usefulness of the on-site detention facility. An under designed on-site detention facility has low effectiveness in reducing flood probability whereas an over designed on-site detention facility is not economical. Thus, in this study, on-site detention facility of three development areas were analysed using two methods namely, the Simplified Method and the Modified Puls Method. From the study outcome, it was found that the Modified Puls Method produced more economical design compared to the Simplified Method. Ultimately, the study outcome has provided the civil engineering industry an insight on the cost effective design method of on-site detention facility to prevent monetary losses in construction of oversized on-site detention facility.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Final Year Report
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Not lost Library of Congress Classification     Reference UMPLIB GAMBANG UMPLIB GAMBANG Reference 08/10/2019   FKASA .S55 2019 r Bc. T000000259 08/10/2019 08/10/2019 Final Year Report
  Not lost Library of Congress Classification       UMPLIB GAMBANG UMPLIB GAMBANG   08/10/2019   CD12300 T000000260 13/08/2020 08/10/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us