Biomethanation of sewage wastewater using ultrasonic memberane anaerobic system (UMAS) / (Record no. 90861)

MARC details
000 -LEADER
fixed length control field 03487ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125105403.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191014t20192019my a|||fram|| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0008120(Local)
Qualifying information hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .A49 2019 r Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Alzubeer, Mohammed Ahmed Mohammed,
Relator term author.
245 10 - TITLE STATEMENT
Title Biomethanation of sewage wastewater using ultrasonic memberane anaerobic system (UMAS) /
Statement of responsibility, etc. Mohammed Ahmed Mohammed Alzubeer
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2019
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2019
300 ## - PHYSICAL DESCRIPTION
Extent x, 41 pages :
Other physical details Illustrations ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Sewage wastewater is hard wastewater that contains a high amount of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solids (TSS) and volatile suspended solids (VSS). These vital parameters should be treated first before it is discharged into any waterways. There are many treatment methods implied until this decade with the traditional approach. Pond system is the most implied method due to its low cost. The sewage wastewater was treating to produce methane gas by using membrane anaerobic digestion method. But there will be membrane fouling problem caused by high amounts of total solids carried by the wastewater. Therefore the operating cost of the treatment plant it will be very high. Thus, Ultrasonic Membrane Anaerobic System (UMAS) is used as an alternative method to overcome this problem. The sewage wastewater was collected from Kuantan Water Indah and acclimatizing for 5 days before running the reactor, The row wastewater parameter was recorded, COD was 164.67 mg/L, and BOD was 17.4 mg/L, and TSS was 31 mg/L, and VSS was 6mg/L, the pH, pressure and temperature was kept being constant during the experiment within the values of 6.5 to 7.5, 2 to 3 bar and 35 to 46 ºC respectively. The performance of Ultrasonic Membrane Anaerobic System UMAS is evaluated on the ability of (UMAS) to treat these parameters. The UMAS must be operated daily for 5 hours operation per day. The experiment is done when the UMAS is achieving a steady state. The steady state is achieved on day 5. The performance of UMAS showed high COD removal efficiency with 97.4%. and BOD removal efficiency with 92%, TSS removal efficiency 97% and VSS removal efficiency 99% and the methane gas composition obtained was about 79%. Based on the result obtained after ten days of the experiment shows that UMAS can treat strength and low wastewater, with no membrane fouling problem and produce methane gas from sewage wastewater. Moreover, further works are required to provide more in-depth understanding of the mechanisms involved to facilitate the development of an optimum system applicable to the field of the wastewater treatment plant.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Final Year Report
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Not lost Library of Congress Classification     Reference UMPLIB GAMBANG UMPLIB GAMBANG Reference 14/10/2019   FKASA .A49 2019 r Bc. T000000285 14/10/2019 14/10/2019 Final Year Report
  Not lost Library of Congress Classification       UMPLIB GAMBANG UMPLIB GAMBANG   14/10/2019   CD12313 T000000286 13/08/2020 14/10/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us