Hydrochemical assessment of ground water quality at Kampong Jaya Gading / (Record no. 90881)

MARC details
000 -LEADER
fixed length control field 02898ntm a2200361 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125105404.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191015t20192019my a|||fram|| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0008301(Local)
Qualifying information hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .A2385 2019 r Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammed Badraddin, Abdulmalek Khled,
Relator term author.
245 10 - TITLE STATEMENT
Title Hydrochemical assessment of ground water quality at Kampong Jaya Gading /
Statement of responsibility, etc. Abdulmalek Khled Mohammed Badraddin
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2019
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2019
300 ## - PHYSICAL DESCRIPTION
Extent viii, 45 pages :
Other physical details illustrations ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. In Malaysia, groundwater is one of the sources of clean water, other than fresh river water and rain. Thus, this research had been done to determine the groundwater quality and also the effective type of well that can contribute to the good quality of groundwater. The parameters were considered such as PH, Electrical Conductivity, Turbidity, TDS, TSS, COD, BOD, manganese, iron, copper, zinc, lead, nitrate, total coliform and E.coli in this study. The water samples were collected from three different wells. The results were compared to the National Drinking Water Quality Standard (NDWQS) to know the class of the groundwater for each well. The result showed that the groundwater had been contaminated by the chromium with concentration of 1.59 mg/L which found in all wells. This result considered as relatively not in very high concentration even the concentration of element is higher than the standard stated by National Drinking Water Quality Standard (NDWOS). Meanwhile. for biological analysis result showed that total coliform and E.coli have highest contamination which was found in open wells with total coliform concentration 28 MPN/100 mL in opened well and 14 MPN/100 mL in closed well .E.coli concentration is 8.6 MPN/100 mL and 0MPN/100 mL in closed wells . As the conclusion, the groundwater quality was harmless from heavy metal concentration but highly contaminated with total coliform and E. coli. Quality of groundwater is equally important to its quantity owing to the suitability of water for various purposes.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Source of heading or term Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Disertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Final Year Report
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG Reference 15/10/2019   FKASA .A2385 2019 r Bc. T000000245 15/10/2019 15/10/2019 Thesis
  Not lost Library of Congress Classification     Reference UMPLIB GAMBANG UMPLIB GAMBANG Reference 15/10/2019   CD12293 T000000246 20/11/2020 15/10/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us