MARC details
| 000 -LEADER |
| fixed length control field |
02791nam a22003377i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251125105523.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
a||||fr|||| 001 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
200225t20192019my ||||f ma|| 001 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0008524(Local) |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKM .A39 2019 r Thesis |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhammad Aizzuddin Abdullah, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Development of temperature-insensitive fibre bragg grating based pressure transducer / |
| Statement of responsibility, etc. |
Muhammad Aizzuddin Abdullah |
| 264 01 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2019 |
| 264 04 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
© 2019 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 91 pages : |
| Other physical details |
illustrations (some color) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Mechanical & Manufacturing Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Master of Science) -- Universiti Malaysia Pahang – 2019 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Pressure sensors are the essential equipment in the field of pressure measurement. In this study, an aluminium diaphragm-based fibre Bragg grating (FBG) pressure transducer with temperature compensation strategy is presented. FBG-based sensors are good for certain applications, such as biomedical, combustion chamber and pressure vessel; particularly those involving harsh enviroment and high electromagnetic disturbance. One of the greatest challenges for utilising an FBG-sensor based transducer is the unstable output spectrum due to temperature variations. This phenomenon results in a huge variation in pressure readings, thus contributing to accuracy problem. To overcome the problem, this study introduced an approach to solve the inconsistency of sensor output by utilising two FBGs that were bonded at the centre of the diaphragm (FBG sensor) and at the base of the pressure transducer (FBG reference). The inconsistency of wavelength was eliminated by normalising the Bragg wavelength variation from the FBG sensor (𝛥𝜆𝐹𝐵𝐺1) with respect to Bragg wavelength variation from the FBG reference (𝛥𝜆𝐹𝐵𝐺2). The results indicated that the FBG pressure transducer had a sensitivity of 2.8485 nm/MPa at room temperature within the range of 22.9°C to 27.8°C and a linear fitting coefficient of 99.97% in a pressure that ranged from 0 MPa to 0.5 MPa. This FBG pressure transducer with temperature compensation technique was proven to be suitable for the pressure measurement of gas with an average error of 2.32% as compared to the conventional pressure gauge available in market. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Mechanical & Manufacturing Engineering |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Disertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Thesis |