MARC details
| 000 -LEADER |
| fixed length control field |
01782nam a2200241 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000037646 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204356.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
090611t2008 my a f m 000 0 eng|d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006179(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905151646 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201107132136 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141628 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141602 |
| Level of effort used to assign classification |
VLOAD |
| -- |
200906111504 |
| -- |
ida84 |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ223.P76 H33 2008 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mohammad Hadi Ismail |
| 245 10 - TITLE STATEMENT |
| Title |
Rain-water PLC based detector and valve switcher/ |
| Statement of responsibility, etc. |
Mohammad Hadi Bin Ismail |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Rain-water PLC based detector and valve switcher |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2008 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
99 p. : |
| Other physical details |
ill. (some col.) , |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Electrical Engineering (Electronics)) -- Universiti Malaysia Pahang - 2008 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The main purpose of this project is to collect clean rain water automatically by using water sensor; solenoid valves, buzzer and water pump that controlled by Programmable Logic Controller (PLC). Below is modeling of the project. When rain fall, sensor 1 will be detect water and make cause valve 1 will be open for 10 second. This is because; we need to flow out the dirty water from the roof firstly. After 10 second, the valve will be close and make cause the rain water will go to the tank A. If sensor 3 detect no water, water from tank A will be pump to the tank B, with condition, sensor 2 must be detect water in tank A firstly. Finally we can use rain water from Tank B for useful purpose like flushing toilets, washing machines, watering gardens, washing cars and etc. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Programmable controllers |