Design and development of a wireless indoor smart energy saving and monitoring system/ (Record no. 94871)

MARC details
000 -LEADER
fixed length control field 04966ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125105812.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201117t20192019my ad||frm||| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0008882(Local)
Qualifying information hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FTeK .K63 2019 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Koay Li Woon,
Relator term author.
245 10 - TITLE STATEMENT
Title Design and development of a wireless indoor smart energy saving and monitoring system/
Statement of responsibility, etc. Koay Li Woon
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2019
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2019
300 ## - PHYSICAL DESCRIPTION
Extent xii, 94 pages :
Other physical details illustrations ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Engineering Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Science ) -- Universiti Malaysia Pahang – 2019
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Smart Homes or Home Automation becomes famous and different new technology begins to emerge recently. A number of improvements make Smart Home better quality and marketed to the public. To allow the Smart Home system more reliable to any places, modification of an existing work building becomes an idea in the society especially in Malaysia. This research describes a system to convert a conventional into an intelligent working area. A Smart System is introduced to reserve energy. Nowadays, the trends show that highly demand electricity in the society. The issue of rapid energy losses has been discussed around the corner. Energy losses bring the impact of soaring prices of electricity and power production reduces. All the consumers have no idea about the reasons of energy losses. In this research, the design of a wireless and reliable indoor smart power saving system is to minimize the energy losses for the work stations area. Not only have that, the system is able to monitor and analyse the power consumption specialised in each of sections in work building. Modification of an existing work building is highly recommended compare to rebuild a building. The cost is lower if apply a system in existing building and brings out an equivalent standard compare to a new building. Some basic equipment which easily to get and purchased with a lower price to produce the system and apply in the work area, to minimize the cost using and maximize the energy saving. A variety of equipment are used include a programmable controller, transceiver module, relay switches, sensors and others to build up the system. The system will control the operation of electrical appliances in work building based on the conditions of offices. The system works also in fully automated and wireless. When there is someone in the office room, the system will turn ON the appliances immediately. However, when there is no one in the office after certain time, the system will turn OFF the appliances. On top of that, the system is portable to use in anywhere. This concept brings the conveniences and easily to save the energy in any work building. The Monitoring System plays a role to monitor the condition of every office room in work building. This monitoring concept is able to detect the occupancy of the staff in real time during working hours. This shows that the valuable and more advances compare to the technology already in market in this research. Moreover, the system will make data analysis according to the results collected in daily working hour. The data analysis will shows the different between before and after the system is applied in work area. From the comparison results, the application of Smart Energy Saving and Monitoring System is reliable to be placed in work area. The requirement to install the system is according to different locations, different identity of user and the period of using the system. Lastly, the results showed that the total energy used was reduced. For example, the total energy used in lecturer hall had reduced 18kWh. A higher percentage of total energy estimated saves up to 50% was showed after the system was applied. The results proved that the system is applicable and reliable to the user in work area. Thus, this system takes into account the architecture of human cognition and it is highly demand in market to achieve a lower energy usage at the same with high quality and comfortable life.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Engineering Technology
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG 17/11/2020   FTeK .K63 2019 r Thesis T000000187 17/03/2021 1 17/11/2020 Thesis
  Not lost Library of Congress Classification     Reference UMPLIB GAMBANG UMPLIB GAMBANG 17/11/2020   CD 12259 T000000188 06/12/2021 1 17/11/2020 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us