MARC details
| 000 -LEADER |
| fixed length control field |
03703nam a2200349 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251125110042.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
a||||fr|||| 001 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
220428t20212021my a|||fram|| 001 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0009329(Local) |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
KK .A45 2021 r Thesis |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Ali Abdallah Ali Emhemed, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Optimal distributed generation and load shedding scheme using artificial bee colony- hill climbing algorithm considering voltage stability and losses indices / |
| Statement of responsibility, etc. |
Ali Abdallah Ali Emhemed |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2021 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
© 2021 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xvi, 207 pages : |
| Other physical details |
illustrations (some color) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
College of Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Doctor of Philosophy) -- Universiti Malaysia Pahang – 2021 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Around the world, the demand is increasing due to industrial activity and advances in both developing and developed countries. This situation has pushed many power system operators to operate their system closer to the voltage stability limits. Increase in power consumption can cause serious problems in electric power systems, such as voltage instability, frequency instability, line overloading, and power system blackouts.Voltage stability index (VSI) is a tool for detecting voltage stability related problems. This work proposes an index of the line voltage stability limits based on Thevenin’s Theorem, which is referred to as the Maximum Line Stability Index (MLSI). The function of MLSI is to estimate the voltage stability condition and determine sensitive lines in power system. To increase voltage stability and improve other aspects of power quality, many power system operators are considering the idea of integrating distributed energy resources into the existing power system. Another part of this work focuses on enhancing the stability of the power system using distributed generator (DG). The proposed solution is based on the optimization method developed from a combination of the Artificial Bee Colony and Hill Climbing algorithms (ABC-HC) to give the optimal placement and sizing of DG units to be deployed in the system. Under severe contingency conditions, such as increase in demand and loss of transmission lines, frequently the problem cannot be solved by just using the DG, the possible solution is to consider load shedding as to reduce the congestion in order to maintain voltage stability in the system. To solve this problem, an optimal load shedding approach, integrated with optimal DG sizing is proposed using the ABC-HC algorithm. This technique can find the load location to be shed, as well as the size of DG. The performance and effectiveness of each proposed solution was tested on IEEE test systems. The simulation results showed that the MLSI index has strong sensitivity to detect the overloaded line in the system and as reliable as other voltage stability indices. Meanwhile, the proposed ABC-HC optimization technique shows its ability to identify the bus location and the optimal active energy injection from the DG with a substantial power loss reduction. Finally, under severe contingency condition, the optimization of DGs and load shedding shows the system able to maintain its voltage stability. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
College of Engineering |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Thesis |