The effect of tree induced suction on slope stability analysis / (Record no. 97818)

MARC details
000 -LEADER
fixed length control field 04667ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125110124.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 221011s2022 my a|||frm||| 00| 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0009363(Local)
Qualifying information hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FTKA .F37 2022 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Farhan Zolkepli,
Relator term author.
245 14 - TITLE STATEMENT
Title The effect of tree induced suction on slope stability analysis /
Statement of responsibility, etc. Muhammad Farhan Zolkepli
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2022
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2022
300 ## - PHYSICAL DESCRIPTION
Extent xxiii, 320 pages :
Other physical details illustrations (some color) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
337 ## - MEDIA TYPE
Media type term computer
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
338 ## - CARRIER TYPE
Carrier type term computer disc
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Doctor of Philosophy in Civil Engineering) -- Universiti Malaysia Pahang – 2022
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Nowadays, many problems regarding slope failure happened due to cutting down of vegetation. The existence of tree on top of slope is very important to increase soil slope stability. This study explore the influence of active root tree zone (Alstonia Angustiloba) located on top of a slope to reduce soil moisture content thus increase the shear strength of soil slope. Soil matric suction generated at the vicinity of the slope due to tree water uptake is the main focus of this study since it will influence the factor of safety (FOS) of slope. This research employed several approaches i.e field monitoring work for soil suction and rainfall collection, laboratory works for soil classification and determining the shear strength parameters of the soil, subsurface investigation using electrical resistivity imaging (ERI), digital mapping using unmanned aerial vehicle (UAV) and verification of actual soil suction pattern with numerical modelling. Field monitoring works were carried out to obtain soil suction data at the selected slope with two conditions (without and with tree on top of the slope). The unsaturated shear strength behaviour under different stress level was investigated, by conducting consolidated isotropic undrained (CIU) test by replicating the actual matric suction monitored at the study area. From this suction pattern, it was proven that the majority of suction changes were greater at the proximity of the tree trunk (1.1 m) and at a shallow depth of 0.25 m. In addition, Electrical Resistivity Imaging (ERI) was conducted on two layouts (horizontal and vertical) of the slope to obtain the subsurface images of the slope. This ERI survey applies two protocols known as Wenner protocol and Schlumberger protocol. These images from ERI were compared to unsaturated soil suction contour generated using GiD software. This study also implement modern methods for soil slope mapping by using unmanned aerial vehicle (UAV). The findings also applied the safety values (FOS) on 18th February 2018 and 22nd February 2018 into the map to study the daily stability values of the slope and considered as the main novelty of this study. Finally, numerical simulation modelling was applied based on the laboratory results to obtain most appropriate condition to replicate tree water uptake within soil slope during dry period. The factor of safety (FOS) of soil slope in 19th February 2018 with tree on top of it reached up to 53 % higher compare to slope without tree. From the results of comparison between suction contour and ERI contour, soil suction contour proved to be more suitable in term of stability analysis, while the ERI contour is more suitable to detect underlying materials underneath the soil based on the ability of materials to resist or allow electric current flow. This study verified the finding from ERI survey with the soil properties of Pahang Matriculation College. ERI prove the existence of clay in the soil which verified the high clay contents (22.8 %) in the soil itself. Finally, an acceptable agreement has been achieved between simulation of numerical modelling and actual suction collected from field monitoring work with a small difference of 5 % only. This research proved high influenced of single tree on top of soil slope to increase soil slope stability by decreasing the existence moisture in the soil itself.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering Technology
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG 11/10/2022   FTKA .F37 2022 r Thesis T000001963 11/10/2022 1 11/10/2022 Thesis
  Not lost Library of Congress Classification   Not for loan   UMPLIB GAMBANG UMPLIB GAMBANG 11/10/2022   CD13145 T000001964 30/01/2023 1 11/10/2022 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my