MARC details
| 000 -LEADER |
| fixed length control field |
02267nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000037658 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204358.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
090611t2008 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006688(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905171510 |
| Level of effort used to assign nonsubject heading access points |
amirul |
| Level of effort used to assign subject headings |
201107132137 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141629 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141603 |
| Level of effort used to assign classification |
VLOAD |
| -- |
200906111655 |
| -- |
kam |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TK1007 .Z85 2008 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Zulkifli Dollah |
| 245 10 - TITLE STATEMENT |
| Title |
Static and dynamic impact of unified power flow controller (UPFC) in electric transmission system / |
| Statement of responsibility, etc. |
Zulkifli Bin Dollah |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Static and dynamic impact of unified power flow controller (UPFC) in electric transmission system |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2008 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
91 p. : |
| Other physical details |
ill. ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Electrical Engineering (Power system)) -- Universiti Malaysia Pahang - 2008 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Unified Power Flow Controller (UPFC) is a part of the Flexible AC Transmission System (FACTS). The main function of UPFC is to control the real and reactive power flow in transmission system, at the same time UPFC will control the voltage at the bus where it’s placed. The main purpose of this project is to analyses the static and dynamic impact of UPFC in transmission line. There have two software that used in this project which are MATLAB and PSCAD/EMTDC software. The MATLAB software used to get the data that can be used to model load flow by using PSCAD/EMTDC software. This modeling is called the steady state model (static). The model in PSCAD used to analyses the impact of UPFC in electric transmission line. For dynamic analyses, the model in steady state condition will apply fault. The analysis for the system is made and then the UPFC is applying to the system and the result will be analyzed. In this project the optimum location for placement of UPFC also has been discuss details. The simulation results show that the UPFC can control the active power, reactive power and the bus voltage which connected to UPFC. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric power systems |
| General subdivision |
Control |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric power transmission |