Flexural performance of built-up cold-formed steel beam (CFSB) filled with concrete / (Record no. 99350)

MARC details
000 -LEADER
fixed length control field 03815ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125110727.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230410t20222022my a|||fr|||| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0009596 (Local)
Qualifying information Hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FTKA .J37 2022 r Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Jarrud Mohamed Muftah Mohamed,
Relator term author.
245 10 - TITLE STATEMENT
Title Flexural performance of built-up cold-formed steel beam (CFSB) filled with concrete /
Statement of responsibility, etc. Jarrud Mohamed Muftah Mohamed
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2022
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2022
300 ## - PHYSICAL DESCRIPTION
Extent xv, 109 pages :
Other physical details illustrations (some color) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
337 ## - MEDIA TYPE
Source rdamedia
Media type term computer
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term computer disc
347 ## - DIGITAL FILE CHARACTERISTICS
Source rda
File type text file
Encoding format PDF
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Science) -- Universiti Malaysia Pahang – 2022
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Cold-formed steel (CFS) became more visible in the construction field with noticeable advantages such as cost-effectiveness, lightweight, easy instalment, low maintenance and corrosion resistance, easily transportable, recyclable, and easy fabrication compared to hot-rolled steel sections. However, the CFS section's associated failure modes, such as local, distortional, lateral-torsional, and global buckling, impeded their application in the construction industry. Therefore, built-up closed CFS beam sections have been introduced with low-cost material such as concrete to mitigate local buckling failure modes and enhance strength and ductility. Prior studies in this line have mainly concentrated on the performance of CFS beams in terms of compression, with the flexural aspect primarily ignored. More importantly, the CFS beam flexural analysis is more complicated in terms of design and failure mode shape. Therefore, this study aimed is to investigate the flexural performance of concrete-filled CFS beam tightened with three bolts using a 3D non-linear finite element analysis. ABAQUS software was used as the finite element tool in this study. The finite element modelling procedures were verified with two previous experimental findings based on the load-deflection response and the failure modes prior to the parametric study. The FE results based on three previous studies show reasonable simulation accuracy of the ultimate load capacity and the mode failures, hence the validation has been performed. Then, parametric study was conducted with six different bolt configurations to investigate the flexural performance of the concrete filled CFS composite beam. The findings of parametric study revealed that increasing the edge bolt spacing in the composite beam to a specific limit resulted in improved performance. Furthermore, filling the built-up CFS section with concrete eliminated any buckling failure modes associated with the CFS section. On the other hand, flexural cracking was the most common failure mode of the infill concrete, with minor concrete crushing at the bottom of the edge-bolt hole. Overall, the results obtained in terms of load capacity, failure modes, and stress development for the CFS built-up section beam tightened with bolts can provide engineers with insight into the various future application possibilities of these different components forming the composite beam and utilization for improving the methodological procedures in the CFS-concrete composite design.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering Technology
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan Reference UMPLIB GAMBANG UMPLIB GAMBANG 10/04/2023   FTKA .J37 2022 r Thesis T000002265 10/04/2023 1 10/04/2023 Thesis
  Not lost Library of Congress Classification   In Transit Reference UMPLIB GAMBANG UMPLIB GAMBANG 10/04/2023   CD 13292 T000002266 10/04/2023 1 10/04/2023 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us