Optical goniometer device for continuous monitoring of the knee movement in physiotherapy application / (Record no. 99371)

MARC details
000 -LEADER
fixed length control field 04142ntm a2200373 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251125110729.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t||||fr|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230411t20222022my a|||fr|||| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0009607 (Local)
Qualifying information Hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
Language of cataloging eng
Transcribing agency UMP
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FTKEE .G43 2022 r Thesis
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Ghassan Maan Salim,
Relator term author.
245 10 - TITLE STATEMENT
Title Optical goniometer device for continuous monitoring of the knee movement in physiotherapy application /
Statement of responsibility, etc. Ghassan Maan Salim
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMP,
Date of production, publication, distribution, manufacture, or copyright notice 2022
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice ©2022
300 ## - PHYSICAL DESCRIPTION
Extent xxiii, 339 pages :
Other physical details illustrations some color ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
337 ## - MEDIA TYPE
Source rdamedia
Media type term computer
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term computer disc
347 ## - DIGITAL FILE CHARACTERISTICS
Source rda
File type text file
Encoding format PDF
500 ## - GENERAL NOTE
General note Faculty of Electrical & Electronics Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Doctor of Philosophy) -- Universiti Malaysia Pahang – 2022
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references
520 3# - SUMMARY, ETC.
Summary, etc. Knee joint is the most crucial among the lower limbs joints due to its exposed location and its major role which carries the entire burden of the body practically our entire life. Hence, by being able to measure the knee joint angle accurately during continuous movement, allows the physiotherapist to detect knee joint damage at early stages before it turns into an injury or permanent scar tissue. Due to the limited number of continuous monitoring devices applicable for diagnosis and treatment stage of the knee, most physicians opted for X-ray and magnetic resonance imaging (MRI) technologies to have some insight on the knee issue before suitable treatment can be recommended. Aside from being expensive for general use of MRI, X-ray on the other hand can cause short-term side effects due to radiation exposure. Knee joint angle measurement devices technologies include but are not limited to the implementation of accelerometer, electrogoniometer, torsiometer, acoustic, visual sensory, and optic fibre. There are many limitations to these technologies that require improvements before they can become clinically applicable such as accuracy issues, limited range of motion measurement, and inability to monitor continuous movement measurement of the knee joint, which have been discussed thoroughly in this research. The need for technologies with higher accuracy, reliability, able to measure the full knee range of motion, applicable for continuous motion measurement and lower cost have always been a crucial factor. The use of optical based devices provides significant contribution in this area due to their advantages such as immunity to electromagnetic interference, lightweight and possibly small sensor setup. However, the application of intensity-based optical fibre sensor for human joint motion detection resulted in limited detection angle, where most sensor are not able to detect angle variation of more than 90ᵒ. To improve this limitation, an optical sensor approach with mechanical-assisted components assembly that translates angular movement to linear movement was developed. The light detection on the photodiode array sensor at different pixels is analysed to represent the angle movement of the knee. The sensor is securely attached to a medical standard knee brace tool to ensure firm sensor placement on the knee area. Based on current study, the proposed optical sensor has a range of motion between 0 to 160ᵒ, with 0.08ᵒ resolution, has a 210.5 sampling rate per second, which allows it to present and record a real time graphical output to demonstrate the knee joint activity performance. Moreover, the proposed device was able to give an excellent internal consistency obtained by Cronbach’s Alpha analysis of 0.967, and has 98.044% correlation with the gold standard goniometer.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Electrical & Electronics Engineering
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 11/04/2023   FTKEE .G43 2022 r Thesis T000002113 11/04/2023 11/04/2023 Thesis
  Not lost Library of Congress Classification     UMPLIB PEKAN UMPLIB PEKAN 11/04/2023   CD13223 T000002114 11/04/2023 11/04/2023 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us