MARC details
| 000 -LEADER |
| fixed length control field |
03868nam a2200373 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251125110741.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
a||||fr|||| 000 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
230614t20232023my a|||fr|||| 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0009474 (Local) |
| Qualifying information |
Hardback |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FTKEE .M39 2023 r Thesis |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mazuina Mohamad, |
| Relator term |
author. |
| 245 12 - TITLE STATEMENT |
| Title |
A development of an optical bilirubin detection system In the visible (vis) region for jaundice diagnosis application / |
| Statement of responsibility, etc. |
Mazuina Mohamad |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2023 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2023 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 115 pages : |
| Accompanying material |
1 CD ROM |
| Other physical details |
Illustration ; |
| Dimensions |
30 cm.+ |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
computer |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
computer disc |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| Source |
rda |
| File type |
text file |
| Encoding format |
PDF |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Electrical & Electronics Engineering Technology |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Doctor of Philosophy) -- Universiti Malaysia Pahang – 2023 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical reference |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This thesis describes the development of an optical fibre sensor for the detection of bilirubin (BR) molecules and measurement of its concentration in the visible (Vis) wavelength region. The concentration which exceeds the normal rate of BR in the human body that can lead to jaundice, and severe of hyperbilirunemia to newborns. Current practices have drawbacks which take longer of time to produce results. Some of the existence techniques are based on the consumption of other element for measuring the BR concentration in the sample. So that, BR molecules is mixed with a particular substance which can give effects to the identification and concentration measurement of BR. This research is carried out to identify the optimum absorption of BR molecules and analyses a cross sensitivity issue which is arise as a BR concentration measurement system based on spectroscopy study. It was developed using an open-path technique where the analytical sample is tested through the transmitting UV-Visible light beam. The experimental setup consists of halogen light source, cuvette holder, cuvette (cell), optical fibre cables and computer to display results. The Spectrasuite software was used in initial set up to display the optimum absorbance of BR. This software was irrelevant to measure the BR concentration in real-time. Therefore, LabVIEW can be used for this purpose. The developed optical sensor was successfully optimized. It is able to measure the various concentration of the four samples which are 50 μmol/L, 100 μmol/L, 150 μmol/L and 200 μmol/L at the particular visible absorption peak at 440 nm with low noise signal. Ratio technique was implemented to solve the cross-sensitivity issue between the BR molecules and Hemoglobin (Hb). Otherwise, the cross-sensitivity issue between carbon dioxide and oxygen can be ignored due to the very low absorption in the visible region. The developed BR concentration measurement system was also compared with the commercial set up system. It is associated with each concentration. It is also defined as a correlation between the measured absorbance produced by both instruments. The error percentage showed less than 3% which is considered as a laboratory standard for the instrument with good precision. By the advantage of LabVIEW, the optical sensor has an ability to measure the BR concentrations in real-time. This is a good potential that the optical sensor can identify the BR molecules and measure its concentration in a fast time response which is around 3s. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Electrical & Electronics Engineering Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Thesis |
| General subdivision |
Dissertations |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Thesis |