Power quality analysis based on harmonic distortion level in FKEE lab, UMP/ Ahmad Kamil Bin Fadir

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: 65 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0006464(Local)
Other title:
  • Power quality analysis based on harmonic distortion level in FKEE lab, UMP [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Electrical Engineering (Power Systems)) -- Universiti Malaysia Pahang - 2009 Abstract: Power quality is defined as any power problem manifested in voltage, current or frequency deviation that results in failure or misoperation of customer equipment. Harmonic is sinusoidal voltage or currents which has frequencies that are integer multiples of the fundamental frequency (frequency at which the supply system is designed to operate, normally 50 or 60 Hz).Firstly the harmonic current and voltage were get at substation board in FKEE lab by using power quality analyzer. After a week, the data transferred to the computer by using FLUKEVIEW software. Then, the data were compared to International Standard which is AS61000.3.6 and IEEE 519 by using Visual Basic (Microsoft Web Developer) to display it. The results show us that all the data were satisfy with the standards. During the study period (between 12 pm until 6 pm) at the lab, there were the peak period of harmonic but from 7 pm to 7 am, the harmonics were lower than before. Its shows us that the usage of the electrical equipment such as computers, lighting, motors were higher during our lab period. So, from the analysis we know when is the peak time of harmonic will occur and the sources of the harmonic. Besides that, we also know about the effect of the harmonic distortion on electrical equipment.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TJ1049 .K36 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000037897
Final Year Report Final Year Report UMPLIB PEKAN CD 3323 | TJ1049 .K36 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000037898

Project paper (Bachelor of Electrical Engineering (Power Systems)) -- Universiti Malaysia Pahang - 2009

Power quality is defined as any power problem manifested in voltage, current or frequency deviation that results in failure or misoperation of customer equipment. Harmonic is sinusoidal voltage or currents which has frequencies that are integer multiples of the fundamental frequency (frequency at which the supply system is designed to operate, normally 50 or 60 Hz).Firstly the harmonic current and voltage were get at substation board in FKEE lab by using power quality analyzer. After a week, the data transferred to the computer by using FLUKEVIEW software. Then, the data were compared to International Standard which is AS61000.3.6 and IEEE 519 by using Visual Basic (Microsoft Web Developer) to display it. The results show us that all the data were satisfy with the standards. During the study period (between 12 pm until 6 pm) at the lab, there were the peak period of harmonic but from 7 pm to 7 am, the harmonics were lower than before. Its shows us that the usage of the electrical equipment such as computers, lighting, motors were higher during our lab period. So, from the analysis we know when is the peak time of harmonic will occur and the sources of the harmonic. Besides that, we also know about the effect of the harmonic distortion on electrical equipment.