Triton-X amphoteric surfactant as drag reducing agent in aqueous media flowing in pipelines with different pipe diameters/ Zainur Azizi Zakaria

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: xix, 72 p. : ill. (some col.) ; 30 cm. + 1 CD-ROMISBN:
  • THE0004925(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: In this study the effect of the presence of a drag reducing agent (DRA) on the pressure drop in co-current horizontal pipes carrying flow of water is investigated. An experimental set-up is erected. The tested fluid was water and aqueous solution of Triton X-100 surfactant with 50 ppm (ppm-part per million), 100 ppm, 200 ppm and 300 ppm weight concentration of Triton X-100. The test section of the experimental set-up is consisted of three different pipe diameter and testing section length. The experimental was doing with 0.5 inch, 1.0 inch, 1.5 inch ID and 0.5 m long, 1.0 m long and 1.5 m long. Water also was pumped with five different fluid flow rates which is for each pipe diameter have a differ values of volumetric flow rate setting. The percent drag reduction (%DR) is calculated using the obtained experimental data, in presence of the DRA. The results show that addition of DRA could be effective up to some doses of DRA. Not only that, with smaller pipe diameter, performances of drag reduction occur is much better than larger pipe diameter. A maximum %DR of about 73 is obtained for 300 ppm concentration of Triton X-100. This is shows that, the energy consumption for pumping system will be decrease about 73%. When the energy consumption is decrease, the costing for installation pumping system also will be decreased.-Author-
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP994 .Z35 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042901
Final Year Report Final Year Report UMPLIB GAMBANG CD 3978 | TP994 .Z35 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042902

Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009

Bibliography : p. 43-44

In this study the effect of the presence of a drag reducing agent (DRA) on the pressure drop in co-current horizontal pipes carrying flow of water is investigated. An experimental set-up is erected. The tested fluid was water and aqueous solution of Triton X-100 surfactant with 50 ppm (ppm-part per million), 100 ppm, 200 ppm and 300 ppm weight concentration of Triton X-100. The test section of the experimental set-up is consisted of three different pipe diameter and testing section length. The experimental was doing with 0.5 inch, 1.0 inch, 1.5 inch ID and 0.5 m long, 1.0 m long and 1.5 m long. Water also was pumped with five different fluid flow rates which is for each pipe diameter have a differ values of volumetric flow rate setting. The percent drag reduction (%DR) is calculated using the obtained experimental data, in presence of the DRA. The results show that addition of DRA could be effective up to some doses of DRA. Not only that, with smaller pipe diameter, performances of drag reduction occur is much better than larger pipe diameter. A maximum %DR of about 73 is obtained for 300 ppm concentration of Triton X-100. This is shows that, the energy consumption for pumping system will be decrease about 73%. When the energy consumption is decrease, the costing for installation pumping system also will be decreased.-Author-