Zinc removal in biofilm reactor with support media / Rahaiminullah Bin Razali

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: xii, 45 p. : ill. (some col.) ; 30 cm. + 1 computer fileISBN:
  • THE0003197(Local)
Other title:
  • Zinc removal in biofilm reactor with support media [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: Zinc removal in biofilm reactor with support media by mixed culture, attract a lot of interest from the public and as well as chemical industry. In this research, biofilm process was selected as a treatment method with using sequencing batchreactor (SBR).This method is better choice when compared in cost of treatment. Atthe beginning of the experiment, the mixed culture was collected from the drain and acclimatized in 10 litres reactor and the growth of mixed cultured is monitored by take suspended solid test. The mixed culture is acclimatized within two months by feed trace amount of glucose and 1mg/L of zinc. The hydraulic retention time (HRT) selected for this research is 5 days. Three parameters were chosen during run theexperiment which was suspended solid (SS) test for monitoring mixed culture growth while chemical oxygen demand (COD) removal and zinc removal for measure the water quality. This research will carry out by controlling the loading rate. The loading rate is choosing from 3 mg/L.d to 5 mg/L.d. The trend of results was determined. Based on result, increasing the loading rate make the all value of parameters decreased. The average value of SS in acclimatize reactor is 2645.39 mg/L. For the treatment reactor, the highest average value of SS is 566.21 mg/L. For COD removal and zinc removal, the highest average was at loading rate 3mg/L.d which is 41.49% and 75.01% respectively. Using Design-Expert programmed, the optimized data obtained. From the Design-Expert data, the zinc removal is 74.38% and the COD removal is 47.73%. The desirability of the lowest parameter of loading rate is 0.81.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TD466 .R34 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042773
Final Year Report Final Year Report UMPLIB GAMBANG CD 3914 | TD466 .R34 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042774

Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009

Bibliography : p. 34-36

Zinc removal in biofilm reactor with support media by mixed culture, attract a lot of interest from the public and as well as chemical industry. In this research, biofilm process was selected as a treatment method with using sequencing batchreactor (SBR).This method is better choice when compared in cost of treatment. Atthe beginning of the experiment, the mixed culture was collected from the drain and acclimatized in 10 litres reactor and the growth of mixed cultured is monitored by take suspended solid test. The mixed culture is acclimatized within two months by feed trace amount of glucose and 1mg/L of zinc. The hydraulic retention time (HRT) selected for this research is 5 days. Three parameters were chosen during run theexperiment which was suspended solid (SS) test for monitoring mixed culture growth while chemical oxygen demand (COD) removal and zinc removal for measure the water quality. This research will carry out by controlling the loading rate. The loading rate is choosing from 3 mg/L.d to 5 mg/L.d. The trend of results was determined. Based on result, increasing the loading rate make the all value of parameters decreased. The average value of SS in acclimatize reactor is 2645.39 mg/L. For the treatment reactor, the highest average value of SS is 566.21 mg/L. For COD removal and zinc removal, the highest average was at loading rate 3mg/L.d which is 41.49% and 75.01% respectively. Using Design-Expert programmed, the optimized data obtained. From the Design-Expert data, the zinc removal is 74.38% and the COD removal is 47.73%. The desirability of the lowest parameter of loading rate is 0.81.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us