A study of acoustic emissions signal events in pedicle screw fixation procedure / Mohd Hizzuan Bin Harun

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: xiv, 62 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0005825(Local)
Other title:
  • A study of acoustic emissions signal events in pedicle screw fixation procedure [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: The purpose of this study is to propose a safe and easy method to help medical practitioner for perforation of hole during pedicle screw fixation procedure by using acoustic emissions technique. Generally in Malaysia, the medical practitioner had a really hard time while doing the pedicle screw fixation procedure when it involved with cervical spine. The cervical spine is the most complicated articular system in the body. The pedicles of the cervical spine are short and thick and become the most critical part during the screw insertion process. For this study, two cervical bovine vertebras were used instead of human vertebrae. The source of the acoustic emissions (AE) signal events was from the breakthrough of the bone tissues and it is was captured using AE sensor with the help of Acoustic Emission Detector Software version 2.1.3. Acoustic emissions signal events showed the different trend in hits results when the signal run through the bone tissues either hard of spongy during the perforation of the bone. By the experiment on the first bone, there were sudden increase of hits occur that tell us the pedicle probe had been breakthrough the interface between the hard and soft bone tissues. Meanwhile, in the experiment on the second bone an indicator is used to estimate the time of penetration level where the crack propagation of the bone tissues interfaces occur and the result showed the time were vary for each hole.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TA418.84 .H59 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000044367
Final Year Report Final Year Report UMPLIB PEKAN CD 4207 | TA418.84 .H59 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000044368

Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009

Bibliography : p. 52-53

The purpose of this study is to propose a safe and easy method to help medical practitioner for perforation of hole during pedicle screw fixation procedure by using acoustic emissions technique. Generally in Malaysia, the medical practitioner had a really hard time while doing the pedicle screw fixation procedure when it involved with cervical spine. The cervical spine is the most complicated articular system in the body. The pedicles of the cervical spine are short and thick and become the most critical part during the screw insertion process. For this study, two cervical bovine vertebras were used instead of human vertebrae. The source of the acoustic emissions (AE) signal events was from the breakthrough of the bone tissues and it is was captured using AE sensor with the help of Acoustic Emission Detector Software version 2.1.3. Acoustic emissions signal events showed the different trend in hits results when the signal run through the bone tissues either hard of spongy during the perforation of the bone. By the experiment on the first bone, there were sudden increase of hits occur that tell us the pedicle probe had been breakthrough the interface between the hard and soft bone tissues. Meanwhile, in the experiment on the second bone an indicator is used to estimate the time of penetration level where the crack propagation of the bone tissues interfaces occur and the result showed the time were vary for each hole.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us