Site investigation, sampling and slope stability analysis at kilometer 141 KL-Kuantan highway / Audi Munir Bin Mahmud

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: xiii, 80 p. : ill. ; 30 cm + 1 computer discISBN:
  • THE0002879(Local)
Other title:
  • Site investigation, sampling and slope stability analysis at kilometer 141 KL-Kuantan highway [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: Recently, the public become more concern about slope failure and landslide. Beside that, the governments try to limit any construction at high risk slope area and enforce the construction at high risk slope to provide ground improvement and slope reinforcement. This response is due to the landslide problem that happened frequently in year 2008. In response to the rising problems, this study has been proposed for the Final Year Project. The objective of this Final Year Project is to determine the basic properties, shear strength and unit weight of slope which is located at kilometer 141 from KL-Kuantan Highway. The analysis then will determine the better option between soil nail and anchor reinforcement since these two methods are commonly used. Based on particle size distribution, the soil at three part of slope are dominant by sandy soil type. The moisture content result for the slope is range 22% to 26%. For plastic limit result, the range is 21% to 25% and for liquid limits results, the range is 43% to 50%. The range of dry unit weight is 11kN/m3 to 12kN/m3 with optimum moisture content is 13% to 18%. Based on this result, toe the slope is the most dense part since the dry unit weight is the highest and lowest optimum moisture content. The average shear strength for lower layer is higher than upper layer which is 93.49kPa for lower layer and 71.76kPa for the upper layer. By using slope/W software, the factor of safety (FOS) of existing slope is determined, which is 2.044. Beside that, analysis shows that soil nail reinforcement will give the higher FOS rather than using anchor reinforcement which is 2.940 for soil nail reinforcement and 2.847 for anchor reinforcement. This probably because the soil nails have a lower load requirement than tieback anchors, and are placed closer together.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TA710.5 .A93 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000046171
Final Year Report Final Year Report UMPLIB GAMBANG CD 4386 | TA710.5 .A93 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000046172

Project paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang - 2009

Bibliography : p. 79-80

Recently, the public become more concern about slope failure and landslide. Beside that, the governments try to limit any construction at high risk slope area and enforce the construction at high risk slope to provide ground improvement and slope reinforcement. This response is due to the landslide problem that happened frequently in year 2008. In response to the rising problems, this study has been proposed for the Final Year Project. The objective of this Final Year Project is to determine the basic properties, shear strength and unit weight of slope which is located at kilometer 141 from KL-Kuantan Highway. The analysis then will determine the better option between soil nail and anchor reinforcement since these two methods are commonly used. Based on particle size distribution, the soil at three part of slope are dominant by sandy soil type. The moisture content result for the slope is range 22% to 26%. For plastic limit result, the range is 21% to 25% and for liquid limits results, the range is 43% to 50%. The range of dry unit weight is 11kN/m3 to 12kN/m3 with optimum moisture content is 13% to 18%. Based on this result, toe the slope is the most dense part since the dry unit weight is the highest and lowest optimum moisture content. The average shear strength for lower layer is higher than upper layer which is 93.49kPa for lower layer and 71.76kPa for the upper layer. By using slope/W software, the factor of safety (FOS) of existing slope is determined, which is 2.044. Beside that, analysis shows that soil nail reinforcement will give the higher FOS rather than using anchor reinforcement which is 2.940 for soil nail reinforcement and 2.847 for anchor reinforcement. This probably because the soil nails have a lower load requirement than tieback anchors, and are placed closer together.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my