Preparation and permeability study of polysulfone membrane for CO2 separation / Ida Nuryani Ibrahim

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2008Description: 63 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0004425(Local)
Other title:
  • Preparation and permeability study of polysulfone membrane for CO2 separation [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) --- Universiti Malaysia Pahang - 2008 Abstract: Polysulfone membrane is one of the potential candidates to be used as membranes for gas separation. With a nonporous and dense membrane structure, the membrane can be applied in a wide range of temperature and pressure. Polysulfone membrane was prepared by mixing a dope, where polysulfone (PSU) polymer was mixed with N, N-Dimetilacetamide (DMAc). Permeability of the membrane was examined by using the gas permeability unit available in the Gas Lab. Four membrane samples have been produce with different characteristics which were membrane A, membrane B, membrane C and membrane D namely. Membrane A is straight away immersed in water for ten second, membrane B was exposed in air and has an immersion time of 1 minute, membrane C was straightly immersed in water for one day while membrane D was exposed to air for one minute and immersed in water for a day. Measured permeability data in polysulfone (glassy polymer) was consistent with literature studies. In this regard, immersion time of membrane gave impact in membrane performance. This behavior was found from CO2 permeability value for membrane A was the lowest and the membrane D gave the highest permeability value. It showed that the permeability of membrane D was the best compared to the other 3 membranes with the permeability of membrane A, B, C and D was 0.0824, 0.0827, 0.0837 and 0.1015 cm/s.bar respectively. From the data and supported theories by various authors, it can be concluded that different immersion time gave impacts to the performance of polysulfone polymer membrane for CO2 separation.-Author
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP248.25.M46 I33 2008 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000031411
Final Year Report Final Year Report UMPLIB GAMBANG CD 2769 | TP248.25.M46 I33 2008 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000031412

Project paper (Bachelor of Chemical Engineering) --- Universiti Malaysia Pahang - 2008

Polysulfone membrane is one of the potential candidates to be used as membranes for gas separation. With a nonporous and dense membrane structure, the membrane can be applied in a wide range of temperature and pressure. Polysulfone membrane was prepared by mixing a dope, where polysulfone (PSU) polymer was mixed with N, N-Dimetilacetamide (DMAc). Permeability of the membrane was examined by using the gas permeability unit available in the Gas Lab. Four membrane samples have been produce with different characteristics which were membrane A, membrane B, membrane C and membrane D namely. Membrane A is straight away immersed in water for ten second, membrane B was exposed in air and has an immersion time of 1 minute, membrane C was straightly immersed in water for one day while membrane D was exposed to air for one minute and immersed in water for a day. Measured permeability data in polysulfone (glassy polymer) was consistent with literature studies. In this regard, immersion time of membrane gave impact in membrane performance. This behavior was found from CO2 permeability value for membrane A was the lowest and the membrane D gave the highest permeability value. It showed that the permeability of membrane D was the best compared to the other 3 membranes with the permeability of membrane A, B, C and D was 0.0824, 0.0827, 0.0837 and 0.1015 cm/s.bar respectively. From the data and supported theories by various authors, it can be concluded that different immersion time gave impacts to the performance of polysulfone polymer membrane for CO2 separation.-Author

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us