Adaptive Embedded Clonal Evolutionary Programming (AECEP) for optimal Distributed Generation (DG) location and sizing in a distribution system / Nur Zahirah Mohd Ali

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2013Description: xvi, 95 p. : ill. ; 30 cm. + 1 CD-ROMISBN:
  • THE0006686(Local)
Subject(s): Online resources: Dissertation note: Thesis (Master of Engineering (Electrical)) -- Universiti Malaysia Pahang – 2013 Abstract: Distributed Generation (DG) has gained increasing popularity as a viable element of electric power systems. DG as a small scale generation sources located at or near load center is usually deployed within the distribution system. Installation of DG has many positive impacts such as reducing transmission and distribution network congestion, differing costly for upgrading process, and improving the overall system performance by reducing power losses and enhancing voltage profiles. To achieve these positive impacts from DG installation, the DG has to be optimally placed and sized. Since last decade, Artificial Intelligence (AI) methods have been used to solve complex DG problems because in most cases they can provide global or near global solution. The major advantage of the AI methods is that they are relatively versatile for handling various qualitative constraints. AI methods mainly include Artificial Neural Network (ANN), Expert System (ES), Genetic Algorithm (GA), Evolutionary Programming (EP), Ant Colony Optimization (ACO) and Particle Swarm Optimization (PSO). The purpose of this thesis is to presents a new technique namely Adaptive Embedded Clonal Evolutionary Programming (AECEP). The objective of the study is to employ AECEP optimization technique for loss minimization and voltage profile monitoring. First step study started by using a conventional technique as a pre-study of DG location and sizing. The Heuristic Search Technique (HST) was developed to empirically determine the location and sizing of DG for the same purpose. This technique was performed on the IEEE 41-Bus and 69-Bus RDS for several cases in terms of loading conditions. The proposed AECEP was implemented for single DG, two DGs and three DGs installation. The result of the proposed AECEP technique was found in a good agreement with those obtained from the EP and AIS in terms of loss minimization and voltage profile improvement.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Thesis Thesis UMPLIB PEKAN TK1006 .Z34 2013 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000075985
Thesis Thesis UMPLIB PEKAN CD 7260 | TK1006 .Z34 2013 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000075986

Thesis (Master of Engineering (Electrical)) -- Universiti Malaysia Pahang – 2013

Bibliography : p. 82-88

Distributed Generation (DG) has gained increasing popularity as a viable element of electric power systems. DG as a small scale generation sources located at or near load center is usually deployed within the distribution system. Installation of DG has many positive impacts such as reducing transmission and distribution network congestion, differing costly for upgrading process, and improving the overall system performance by reducing power losses and enhancing voltage profiles. To achieve these positive impacts from DG installation, the DG has to be optimally placed and sized. Since last decade, Artificial Intelligence (AI) methods have been used to solve complex DG problems because in most cases they can provide global or near global solution. The major advantage of the AI methods is that they are relatively versatile for handling various qualitative constraints. AI methods mainly include Artificial Neural Network (ANN), Expert System (ES), Genetic Algorithm (GA), Evolutionary Programming (EP), Ant Colony Optimization (ACO) and Particle Swarm Optimization (PSO). The purpose of this thesis is to presents a new technique namely Adaptive Embedded Clonal Evolutionary Programming (AECEP). The objective of the study is to employ AECEP optimization technique for loss minimization and voltage profile monitoring. First step study started by using a conventional technique as a pre-study of DG location and sizing. The Heuristic Search Technique (HST) was developed to empirically determine the location and sizing of DG for the same purpose. This technique was performed on the IEEE 41-Bus and 69-Bus RDS for several cases in terms of loading conditions. The proposed AECEP was implemented for single DG, two DGs and three DGs installation. The result of the proposed AECEP technique was found in a good agreement with those obtained from the EP and AIS in terms of loss minimization and voltage profile improvement.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us