Comparison study of corrosion measurement technique / Fadli Mislan@Mishadi

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2013Description: xvi, 46 p. : ill. (some col.) ; 30 cmISBN:
  • THE0005877(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2013 Abstract: Corrosion monitoring tests were carried out to compare some of electrochemical techniques and non-electrochemical technique to measuring the corrosion rate and to study the uncertainty of the these techniques. Each of technique have their errors from the experimental method and equation of the theory. In atmospheric condition, 3.5% wt of NaCl will be used as solution for electrochemical techniques,while for weight loss will immersed in that solution at certain time of period. The data from electrochemical method were analyzed by using Ivman software and to be compare the result of each technique. The experiment were carried out at atmospheric condition and at room temperature.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TA462 .F33 2013 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000086254
Final Year Report Final Year Report UMPLIB PEKAN CD 8068 | TA462 .F33 2013 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000086255

Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2013

Bibliography : p. 43-44

Corrosion monitoring tests were carried out to compare some of electrochemical techniques and non-electrochemical technique to measuring the corrosion rate and to study the uncertainty of the these techniques. Each of technique have their errors from the experimental method and equation of the theory. In atmospheric condition, 3.5% wt of NaCl will be used as solution for electrochemical techniques,while for weight loss will immersed in that solution at certain time of period. The data from electrochemical method were analyzed by using Ivman software and to be compare the result of each technique. The experiment were carried out at atmospheric condition and at room temperature.