Analysis of squat shear wall with different dimensions and position of opening under different type of static loads / Ang Yip Hong

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2015Description: xv, 61 p. : ill. (some col.) ; 30 cm. + 1 CD ROMISBN:
  • THE0000288(Local)
Subject(s): Online resources: Dissertation note: Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015 Abstract: Shear walls are usually used in high-rise building or building on high frequency of wind area as the structural element to restrain lateral forces. Openings are created on the shear wall for the architecture, ventilation or mechanical and electrical purposes. With the existence of the opening, the strength of the wall is reduced by the reduction in concrete area and the discontinuity of the reinforcement due to opening which may lead to structural failure. The main objective is to study the effect of size and position of the opening towards the structural behavior of the shear wall under different type of static loads. The analysis is done using the software ANSYS12.0. The samples are SW1, SW2, SW3, SW4, SW5, SW6, SW7 and SW8 where SW1 is solid shear wall while SW2, SW3, SW4, SW5, SW6, SW7 and SW8 are shear walls with different size and position of opening. They are analyzed by using 2 different types of loads which are uniformly distributed axial load and uniformly lateral load. From the same magnitude of loads applied towards the shear walls, they are compared by the cracking pattern and the stress distribution. Under both axial and lateral loads, it shows a significance results that the shear wall with greater opening size shows less efficiency. The position of opening further from the support shows a more significance effect towards the strength of the wall from axial load but opposite from the lateral load. Besides, the closer the position of the shear wall to the load, the less efficient it is. As a conclusion from the results, the most suitable position of the opening on the shear wall is further from the support and the loads and it shows that there is a significance effect even from a smallest opening
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG FKASA .A54 2015 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000104189
Final Year Report Final Year Report UMPLIB GAMBANG CD 9280 | FKASA .A54 2015 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000104190

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015

Bibliography : p. 60-61

Shear walls are usually used in high-rise building or building on high frequency of wind area as the structural element to restrain lateral forces. Openings are created on the shear wall for the architecture, ventilation or mechanical and electrical purposes. With the existence of the opening, the strength of the wall is reduced by the reduction in concrete area and the discontinuity of the reinforcement due to opening which may lead to structural failure. The main objective is to study the effect of size and position of the opening towards the structural behavior of the shear wall under different type of static loads. The analysis is done using the software ANSYS12.0. The samples are SW1, SW2, SW3, SW4, SW5, SW6, SW7 and SW8 where SW1 is solid shear wall while SW2, SW3, SW4, SW5, SW6, SW7 and SW8 are shear walls with different size and position of opening. They are analyzed by using 2 different types of loads which are uniformly distributed axial load and uniformly lateral load. From the same magnitude of loads applied towards the shear walls, they are compared by the cracking pattern and the stress distribution. Under both axial and lateral loads, it shows a significance results that the shear wall with greater opening size shows less efficiency. The position of opening further from the support shows a more significance effect towards the strength of the wall from axial load but opposite from the lateral load. Besides, the closer the position of the shear wall to the load, the less efficient it is. As a conclusion from the results, the most suitable position of the opening on the shear wall is further from the support and the loads and it shows that there is a significance effect even from a smallest opening