Current measurement of engine oil with various gap length electrode / by Benedick Conolius ak Gabriel Addris
Material type:
Computer filePublication details: Kuantan, Pahang : UMP, 2016Description: 1 computer disc : digital data ; 12 cmISBN: - THE0005135(Local)
- Benedick Conolius Gabriel Addris
| Item type | Current library | Call number | Copy number | Status | Date due | Barcode | |
|---|---|---|---|---|---|---|---|
Final Year Report
|
UMPLIB PEKAN | FKEE .B46 2016 r Bc | CD 10714 (Browse shelf(Opens below)) | 1 | Not for loan | 0000117730 |
Faculty of Electrical and Electronics Engineering
Project Paper (Bachelors of Electrical Engineering (Power Systems)) -- University Malaysia Pahang – 2016
This thesis present about the conductivity of engine oil that exist when there is conductive particle involve in the viscosity of lubricant oil. Its also known as hydrocarbon particles. Experiment for voltage-current characteristic normally done by using electrode to detect the current or conductivity of lubricant oil. For this experiment, the gap length of electrode has been design from 1mm until 10mm. The electrode has been printed to PCB board so that easy to be conducted during experiment. Different kilometre of the sample lubricant oil has been collected after their utilization in transport system. There are two types of lubricant oil that being tested that are motorcycle’s and car’s lubricant oil. The high voltage DC supply will be connected to electrode. All the data obtained for each gap length of electrode has been recorded.
Item in pdf format