Seismic performance of elevated water tank under earthquake loading / Nurul Atikha Khariul Abidin

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2017Description: xvi, 65 p. : ill. (some col.) ; 30 cm. + 1 CD-ROMISBN:
  • THE0000305(Local)
Subject(s): Online resources: Dissertation note: Project Paper (Bachelors of Civil Engineering (Hons.)) -- Universiti Malaysia Pahang – 2017 Abstract: The elevated water tank is very important structure and it consist various type. Water tank is designed to store quantity of liquid such as liquid petroleum and water to supply to the public or residential area. The design also must resist earthquake loading since Malaysia have been experienced a few earthquake event due to the earthquake loading that occurred in the neighboring countries. Back in 2015, the earthquake has occurred in Ranau, Sabah which affected the building structure and geological changes. However, most of the structure designed in Malaysia did not consider the earthquake loading. So, this study will focused on the seismic performance on reinforced concrete of elevated water tank under earthquake loading. The main objective of this research is to study the seismic behavior of elevated water tank structure in Malaysia region under far field earthquake loading. The structure will be design and simulate by using computer software, SAP2000.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG FKASA .A85 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000117498
Final Year Report Final Year Report UMPLIB GAMBANG CD 10653 | FKASA .A85 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000117499

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelors of Civil Engineering (Hons.)) -- Universiti Malaysia Pahang – 2017

Bibliography : p. 64-65

The elevated water tank is very important structure and it consist various type. Water tank is designed to store quantity of liquid such as liquid petroleum and water to supply to the public or residential area. The design also must resist earthquake loading since Malaysia have been experienced a few earthquake event due to the earthquake loading that occurred in the neighboring countries. Back in 2015, the earthquake has occurred in Ranau, Sabah which affected the building structure and geological changes. However, most of the structure designed in Malaysia did not consider the earthquake loading. So, this study will focused on the seismic performance on reinforced concrete of elevated water tank under earthquake loading. The main objective of this research is to study the seismic behavior of elevated water tank structure in Malaysia region under far field earthquake loading. The structure will be design and simulate by using computer software, SAP2000.