Effects of ph in mercury nitrate treatment using membrane system with biological pretreatment / Mohd Yusnizam Yusof

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2008Description: 49 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0004245(Local)
Other title:
  • Effects of ph in mercury nitrate treatment using membrane system with biological pretreatment [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) --- Universiti Malaysia Pahang - 2008 Abstract: Wastewater come from industry containing mercury is very dangerous. We need to treat the wastewater effectively to avoid the toxic. Membrane usage in wastewater treatment has increase due to its ability to filtrate the unwanted particle. The manipulating of parameters of membrane can give the better result other then changing the type of membrane for filtration of mercury in wastewater. Using P.putida as the pretreatment or volatilizing agent and continue with alternation of pH value for mercury solution, this technique seems easily can reach the target of removing mercury to the minimum level of permitted. According to experiment, the pretreatment stage decreases the Hg solution from concentration of 250ppb to 8ppb. Then, continue with Membrane separation, the concentration was decrease to 0ppb within pH8 to pH9. So, as conclusion, the best pH for operating membrane to filtrate mercury wastewater is pH8 to 9. This is because membrane operates at neutral or base condition. -Author
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP159.M4 M64 2008 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000031477
Final Year Report Final Year Report UMPLIB GAMBANG CD 2802 | TP159.M4 M64 2008 rs Thesis (Browse shelf(Opens below)) 1 Not for loan 0000031478

Project paper (Bachelor of Chemical Engineering) --- Universiti Malaysia Pahang - 2008

Wastewater come from industry containing mercury is very dangerous. We need to treat the wastewater effectively to avoid the toxic. Membrane usage in wastewater treatment has increase due to its ability to filtrate the unwanted particle. The manipulating of parameters of membrane can give the better result other then changing the type of membrane for filtration of mercury in wastewater. Using P.putida as the pretreatment or volatilizing agent and continue with alternation of pH value for mercury solution, this technique seems easily can reach the target of removing mercury to the minimum level of permitted. According to experiment, the pretreatment stage decreases the Hg solution from concentration of 250ppb to 8ppb. Then, continue with Membrane separation, the concentration was decrease to 0ppb within pH8 to pH9. So, as conclusion, the best pH for operating membrane to filtrate mercury wastewater is pH8 to 9. This is because membrane operates at neutral or base condition. -Author

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us