Finite element analysis on reinforced concrete column with transverse openings / Tan Keen Hong

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2017Copyright date: © 2017Description: ix, 43 pages : illustrations (some color), charts ; 30 cm. + 1 CD-ROMContent type:
  • text
  • text
Media type:
  • unmediated
  • computer
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0000764(Local)
Subject(s): Dissertation note: Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017 Abstract: In construction, openings and holes are drilled to place ducts and pipes for accommodation of services such as electricity, water supply, telecommunication, air conditioning and so on. The presence of such openings may influence the performance of reinforced concrete column, especially from the aspect of load carrying capacity. This study mainly focus on the deflection and crack patterns of reinforced concrete column having opening with different sizes and opening in different locations. Study was conducted on columns specimens with rectangular cross-section of 300 mm x 300 mm and 3800 mm height. All columns specimens were reinforced with longitudinal reinforcement of 4H 20, transverse reinforcement of shear links with 6 mm diameter and 250 mm spacing. Finite element analysis was conducted to study the behaviour of the reinforced concrete column using ANSYS software. The load is applied until the failure of the column models. The result shows that the deflection or the deformation of the control column is the highest and the deflection of the column decreases when the opening size of column increases. The deflection is the highest when opening located in the center of column span. For cracks pattern, more cracks are formed when the opening size increases and when the opening located closer to the applied load.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG FKASA .T55 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122098
Final Year Report Final Year Report UMPLIB GAMBANG CD 11129 | FKASA .T55 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122099

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017

Includes bibliographical references

In construction, openings and holes are drilled to place ducts and pipes for accommodation of services such as electricity, water supply, telecommunication, air conditioning and so on. The presence of such openings may influence the performance of reinforced concrete column, especially from the aspect of load carrying capacity. This study mainly focus on the deflection and crack patterns of reinforced concrete column having opening with different sizes and opening in different locations. Study was conducted on columns specimens with rectangular cross-section of 300 mm x 300 mm and 3800 mm height. All columns specimens were reinforced with longitudinal reinforcement of 4H 20, transverse reinforcement of shear links with 6 mm diameter and 250 mm spacing. Finite element analysis was conducted to study the behaviour of the reinforced concrete column using ANSYS software. The load is applied until the failure of the column models. The result shows that the deflection or the deformation of the control column is the highest and the deflection of the column decreases when the opening size of column increases. The deflection is the highest when opening located in the center of column span. For cracks pattern, more cracks are formed when the opening size increases and when the opening located closer to the applied load.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us