Effect of electrolyte addition and type of solvents used on the quality of nanofiber scaffold / Khoo Ying Siew

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2017Copyright date: © 2017Description: xiii, 58 pages : illustrations (some color) ; 30 cm. + 1 CD-ROMContent type:
  • text
  • text
Media type:
  • unmediated
  • computer
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0000931(Local)
Subject(s): Dissertation note: Project Paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2017 Abstract: Nanofiber-based scaffolding systems are now can mimic the natural extracellular matrix (ECM) of desired tissue to be regenerated and can replace organ transplantation in future. The objective of this study is to determine effect of electrolyte addition and type of solvents used on the quality of nanofibers scaffold. Besides that, the research will proceed to the fabrication of drug embedded nanofibers mat to detect the presence of the drug dissolved in nanofibers mat. In this study, needleless electrospinning technique is applied by using the advanced equipment called Elmarco Nanospider™ to fabricate nanofibers scaffold. Meanwhile, polyethylene oxide (PEO) and polycaprolactone (PCL) polymers were used in this studied. PEO solution was undergoes surface morphology studied by determine the effect of concentration and effect of additional electrolyte on the quality of nanofibers. While PCL polymer was used in study the effect of using different kind of solvents on the quality of nanofibers and also fabrication of drug embedded nanofibers. From the result, PEO 2 obtained a low diameter range of 100 nm to 125 mm and no bead formed compare to PEO 1. While for PEO 3 that contained electrolyte composition, it obtained a 75 nm to 100 nm diameter compare to PEO 2. For PCL that dissolve with DCM, nanofibers obtained were in range of 100nm to 300nm and smooth compare to PCL mixed with DMF and CHCl₃. However, since PEO cannot dissolve completely with curcumin and titanocene drug, PCL is used in this drug fabrication. PCL that mixed with curcmin obtained a higher existence with 18.79% in the nanofibers mat compare to drug titanocene with only 5.586%. In this study, SEM, Image J, FTIR and EDX were used in characterization study of nanofibers. As a conclusion, electrolyte addition can increase the conductivity and DCM solution with low boiling point can eject the solution more easily to the collector.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG FKKSA .K46 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122224
Final Year Report Final Year Report UMPLIB GAMBANG CD 11192 | FKKSA .K46 2017 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122225

Faculty of Chemical & Natural Resources Engineering

Project Paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2017

Includes bibliographical references

Nanofiber-based scaffolding systems are now can mimic the natural extracellular matrix (ECM) of desired tissue to be regenerated and can replace organ transplantation in future. The objective of this study is to determine effect of electrolyte addition and type of solvents used on the quality of nanofibers scaffold. Besides that, the research will proceed to the fabrication of drug embedded nanofibers mat to detect the presence of the drug dissolved in nanofibers mat. In this study, needleless electrospinning technique is applied by using the advanced equipment called Elmarco Nanospider™ to fabricate nanofibers scaffold. Meanwhile, polyethylene oxide (PEO) and polycaprolactone (PCL) polymers were used in this studied. PEO solution was undergoes surface morphology studied by determine the effect of concentration and effect of additional electrolyte on the quality of nanofibers. While PCL polymer was used in study the effect of using different kind of solvents on the quality of nanofibers and also fabrication of drug embedded nanofibers. From the result, PEO 2 obtained a low diameter range of 100 nm to 125 mm and no bead formed compare to PEO 1. While for PEO 3 that contained electrolyte composition, it obtained a 75 nm to 100 nm diameter compare to PEO 2. For PCL that dissolve with DCM, nanofibers obtained were in range of 100nm to 300nm and smooth compare to PCL mixed with DMF and CHCl₃. However, since PEO cannot dissolve completely with curcumin and titanocene drug, PCL is used in this drug fabrication. PCL that mixed with curcmin obtained a higher existence with 18.79% in the nanofibers mat compare to drug titanocene with only 5.586%. In this study, SEM, Image J, FTIR and EDX were used in characterization study of nanofibers. As a conclusion, electrolyte addition can increase the conductivity and DCM solution with low boiling point can eject the solution more easily to the collector.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us