Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete / Mohammad Asyraf Mohd Faridi Yusli

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2018Description: ix, 29 pages : illustrations (some color) ; 30 cm. + 1 CD ROMContent type:
  • text
Media type:
  • unmediated
  • computer
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0000318(Local)
Subject(s): Dissertation note: Project Paper (Bachelor Degree in Civil Engineering) -- Universiti Malaysia Pahang – 2018 Abstract: Foamed concrete is categorized as a lightweight concrete containing air voids. The only difference is that foamed concrete does not contain coarse aggregate in its mixture. Foamed concrete is produced by inducing foam into the slurry of cement mixing with silica sand. In practice, the cement is usually replace with lime. Processed Spent Bleaching Earth (PSBE) is one of the latest Crude Palm Oil (CPO) product. After it has been degummed and bleached, it will come in fine particle and it is classified as a good pozzolanic material. The study investigates the suitability of PSBE as partial cement replacement. The scope of study includes the thermal conductivity and porosity percentage. 10%, 20% and 30% of PSBE will be replacing cement. Foaming agent is used to form air void in foamed concrete. The results turns out that for thermal for 10% PSBE cement replacement at 28 days gets the best reading which is 0.52 W/m.K. For porosity, the result shows that porosity for 30% PSBE foamed concrete achieved the result at 90 days with 17.9% compared to controlled sample. 21.4%. Foamed concrete density also increase when the PSBE percentage increase. Generally thermal conductivity and porosity percentage is one of pozzolanic material characteristic and this study will emphasize this two aspect.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG FKASA .A897 2018 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122826
Final Year Report Final Year Report UMPLIB GAMBANG CD 11296 | FKASA .A897 2018 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000122827

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelor Degree in Civil Engineering) -- Universiti Malaysia Pahang – 2018

Includes bibliographical references

Foamed concrete is categorized as a lightweight concrete containing air voids. The only difference is that foamed concrete does not contain coarse aggregate in its mixture. Foamed concrete is produced by inducing foam into the slurry of cement mixing with silica sand. In practice, the cement is usually replace with lime. Processed Spent Bleaching Earth (PSBE) is one of the latest Crude Palm Oil (CPO) product. After it has been degummed and bleached, it will come in fine particle and it is classified as a good pozzolanic material. The study investigates the suitability of PSBE as partial cement replacement. The scope of study includes the thermal conductivity and porosity percentage. 10%, 20% and 30% of PSBE will be replacing cement. Foaming agent is used to form air void in foamed concrete. The results turns out that for thermal for 10% PSBE cement replacement at 28 days gets the best reading which is 0.52 W/m.K. For porosity, the result shows that porosity for 30% PSBE foamed concrete achieved the result at 90 days with 17.9% compared to controlled sample. 21.4%. Foamed concrete density also increase when the PSBE percentage increase. Generally thermal conductivity and porosity percentage is one of pozzolanic material characteristic and this study will emphasize this two aspect.