The effect of pipe length on the percentage drag reduction for water flowing into pipes with different diameters / Lim Meow Suan

By: Material type: TextTextPublication details: Kuantan : UMP, 2009Description: 49 p. : ill. ; 30 cm. + 1 computer discISBN:
  • THE0004324(Local)
Other title:
  • The effect of pipe length on the percentage drag reduction for water flowing into pipes with different diameters [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2009 Abstract: Fluids are very common and widely used in various industry processes. The only way to transfer fluids is to use pipe. During the transfer, the turbulent flow in pipe always causes a phenomenon called drag. However, this effect could be reduced by addition of Drag Reduction Agents (DRA’s). This study is aimed to provide a clear understanding of the effects of various pipe lengths and pipe diameter on the percentage of drag reduction based on experimental work. In this work, an anionic surfactant, Sodium Dodecyl Sulfate (SDS) will be used as a DRA’S to investigate the purpose as stated above. An experimental apparatus consisting of two tanks, pump, pressure drop indicator, flow meter, test specimen pipe and piping network are set up. The parameters of investigation include concentration of the additive (100, 300 and 500 ppm), different pipe lengths (0.5, 1.0, 1.5, and 2.0 m) as well as different pipe diameters (0.5, 1.0, 1.5 in) at different water flow rates. Through the equivalent altered scale, some interesting results may be discovered.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP245.S7 L56 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042925
Final Year Report Final Year Report UMPLIB GAMBANG CD 3990 | TP245.S7 L56 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042926

Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2009

Fluids are very common and widely used in various industry processes. The only way to transfer fluids is to use pipe. During the transfer, the turbulent flow in pipe always causes a phenomenon called drag. However, this effect could be reduced by addition of Drag Reduction Agents (DRA’s). This study is aimed to provide a clear understanding of the effects of various pipe lengths and pipe diameter on the percentage of drag reduction based on experimental work. In this work, an anionic surfactant, Sodium Dodecyl Sulfate (SDS) will be used as a DRA’S to investigate the purpose as stated above. An experimental apparatus consisting of two tanks, pump, pressure drop indicator, flow meter, test specimen pipe and piping network are set up. The parameters of investigation include concentration of the additive (100, 300 and 500 ppm), different pipe lengths (0.5, 1.0, 1.5, and 2.0 m) as well as different pipe diameters (0.5, 1.0, 1.5 in) at different water flow rates. Through the equivalent altered scale, some interesting results may be discovered.