Permeability and selectivity study of polysulfone membrane for gas separation / Farhana Binti Hasbullah

By: Material type: TextTextPublication details: Kuantan : UMP, 2009Description: 60 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0004281(Local)
Other title:
  • Permeability and selectivity study of polysulfone membrane for gas separation [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2009 Abstract: Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion process. Eight different samples were tested. The permeability of the membranes were tested using the gas permeation unit with pressure of 1.5-2.5 bar and were tested with CO2, CH4, N2 and also O2. Among all these eight types of membrane tested, several show that the behavior of polysulfone membrane to permeate CO2 relies on the treatment that the membranes undergo and the temperature of the coagulation bath. Thus, the most excellent value of permeability for CO2 among eight types of membranes tested was 4.98 x 10-3 cm3/cm2.s.cmHg which was PSU membrane immersed in a 4°C coagulation bath and treated with polydimethylsiloxane (PDMS) as a coating agent with the selectivity value of 1.36.From the data and result collected it is to be proved that temperature of coagulation bath and also the coating agent for membrane treatment play a major role in affecting PSU membrane permeability and selectivity as a whole.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP242 .F37 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042869
Final Year Report Final Year Report UMPLIB GAMBANG CD 3962 | TP242 .F37 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042870

Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2009

Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion process. Eight different samples were tested. The permeability of the membranes were tested using the gas permeation unit with pressure of 1.5-2.5 bar and were tested with CO2, CH4, N2 and also O2. Among all these eight types of membrane tested, several show that the behavior of polysulfone membrane to permeate CO2 relies on the treatment that the membranes undergo and the temperature of the coagulation bath. Thus, the most excellent value of permeability for CO2 among eight types of membranes tested was 4.98 x 10-3 cm3/cm2.s.cmHg which was PSU membrane immersed in a 4°C coagulation bath and treated with polydimethylsiloxane (PDMS) as a coating agent with the selectivity value of 1.36.From the data and result collected it is to be proved that temperature of coagulation bath and also the coating agent for membrane treatment play a major role in affecting PSU membrane permeability and selectivity as a whole.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us